SELL PATIENT MONITOR
15 inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
1.13 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
2. Efficient resistance to interference of defibrillator and electrosurgical cautery;
3. SPO2 can testing for 0.1% Weak;
4. RA-LL impedance Respiration;
5. Trend Coexist Display;
6. OxyCRG Dynamic View Display;
7. Bed to Bed view Display;
8. Networking capacity and nurse calling system;
9. Options of printing, IBP, VGA and EtCO2;
10. UP to 4 hours working capacity of built-in rechargeable battery;
11.15" high resolution color TFT LCD display;
12. Large volume of tabular and graphic trends information storage and easy to recall;
13. Anti-ESU, anti- defibrillator;
14. Capture dynamic waveforms.
Technical specification:
ECG
Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2ch
Lead mode: 3 Leads (R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1ch
Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto
HR and Alarm
Range
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1bpm, which great
Resolution: 1 bpm
Sensitivity: > 200 (uV P-P)
Differential Input Impedance: > 5 MΩ
CMRR
Monitor: > 105 dB
Operation: > 105 dB
Diagnosis: > 85 dB
Electrode offset potential: ±300mV
Leakage Current: < 10uA
Baseline Recovery: < 3 S after Defi.
ECG Signal Range: ±8 m V (Vp-p)
Bandwidth
Surgery: 1 ~ 15 Hz
Monitor: 0.5 ~ 35 Hz
Diagnostic: 0.05 ~ 100 Hz
Calibration Signal: 1 (mV p-p), Accuracy: ±5%
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available
RESPIRATION
Method: Impedance between R-F (RA-LL)
Differential Input Impedance: >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 – 2.5 KΩ
Bandwidth:0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult: 0 ~ 120 rpm
Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy: ±2 rpm
Apean Alarm: 10 ~ 40 S
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,
120, 180, 240,480 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric Mode
SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150 mmHg
MEAN: 20 ~ 165 mmHg
Neonatal Mode
SYS: 40 ~ 135 mmHg
DIA: 10 ~ 100 mmHg
MEAN: 20 ~ 110 mmHg
Resolution Pressure: 1mmHg
Accuracy Pressure Maximum Mean error: ±5mmHg
Maximum Standard deviation: ±8mmHg
Overpressure Protection
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mmHg
Neonatal Mode: 147±3 mmHg
SpO2
Measuring Range: 0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100% ±2 %
0% ~ 69% unspecified
Actualization interval: about 1 Sec.
Alarm Delay: 10 Sec.
Pulse Rate
Measuring and Alarm Range: 20~300bpm
Resolution: 1bpm
Accuracy: ±2bpm
TEMPERATURE
Channel: 2
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1°C
Accuracy: ±0.1°C
Actualization interval: about 1 Sec.
Average Time Constant: <10 Sec.</span>
IBP
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0 ~ 300 mmHg
PA: -6 ~ 120 mmHg
CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
P1/P2: -10 ~ 300 mmHg
Press Sensor
Sensitivity: 5uV/V/mmHg
Impedance: 300-3000Ω
Resolution: 1 mmHg
Accuracy: ±2% or ±1mmHg, which great
Actualization interval: about 1 Sec
Standard Packing List:
5-lead ECG cable (including RESP)
Adult finger SpO2 sensor
Adult NIBP cuff
NIBP extension tube
TEMP sensor
AC power adaptor
ECG electrodes
Operation instruction
Selectable Accessory:
Child finger SPO2 sensor
Child NIBP cuff
Neonate NIBP cuff
Personne à contacter : Rachel Zhang, 86 755 27196156
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de SELL PATIENT MONITOR Rechercher dans la catégorie : Médical Rechercher dans la catégorie : sell, patient, monitor |
Mardi 14 février 2023
405nm is widely using in disinfection, bacterial disease cure,or microbial infection prevention etc.It does no harm to human. But it's blue not friendly for eye view. Feton LED chip model COB SW1919-40W-40FR90 emits this disinfection blue light as white.Lighting while disinfection...
Foshan Feiliu Enterprise Management co.LTD
- 528300 - Foshan
- 86 757 29311003
Mardi 23 novembre 2021
Quantité : 100 min. - Prix : 15 usd
Nous sommes fabricant de cuisinières à gaz (cuisinières à gaz), de machines à baratte (beurre de traite) de Turquie depuis 2013. Notre usine date de 1985 avec l'enroulement de moteur électrique que nous utilisons maintenant dans nos machines à baratte. Dans le même temps, nous sommes...
AKSA EV ESYALARI LTD STI
- 38070 - KAYSERI
- +905411897742
Mercredi 21 octobre 2020
Shining Jins Enterprise Co., Ltd. specializing in manufacturing & designing cold forge Pole piece (T-Yoke) for Loud-Speakers and alarms raw driver in Taiwan. Production capacity: T-Yoke/Pole Piece : Diameter of Piece : 28mm up to 250mm Diameter of Pole : 10mm up to 70mm Length of Pole ...
Shining Jins Enterprise Co., Ltd.
- jsicyoke
- 330 - Taoyuan City
- +88 6 33 61 06 38
Paiement sécurisé