SANITARY HEAT EXCHANGER
SANITARY HEAT EXCHANGER
The wfi sanitary heat exchanger (sterile double tube plate heat exchanger) is designed to work under the working conditions with the highest sanitary requirements, and the double tube plate structure design is adopted. The port of the wfi heat exchanger adopts quick installation or flange structure, which effectively avoids the retention of liquid medicine at the connection between the heat exchanger and the pipeline, realizes the real full emptying design, and also makes the equipment disassembly convenient. The unique design of double tube sheet makes it easy to completely empty and keep the wfi heat exchange tube clean, which can ensure the complete separation of the shell side and tube side media, without internal welding points, and effectively eliminate the cross contamination between products and wfi heat exchange media. It is not polluted and can detect leakage, thus avoiding the risk of cross contamination of conventional wfi heat exchanger.
Technical Data of Sanitary Heat Exchanger
Heat Exchange Area |
0.5—15m2 |
Design Temperature |
max 165℃ |
Design Press |
max 1.6MPa |
Surface Treatment |
Ra=0.25—0.5。 |
Soldering standard |
EN-288-3,EN287-1 |
Mounting Type |
Horizontal or vertical installation. |
OPERATING PRINCIPLES OF SANITARY HEAT EXCHANGER
Operating Principles of Sanitary Heat Exchanger
Working Principle
The material flows through the inside of the sanitary heat exchange tube,
Pharmaceutical Water Systems
and the refrigerant or heat medium flows through the outside of the heat exchange tube in the opposite direction. The end of the heat exchange tube is fastened with double tube plates, and serves as a leakage monitoring point to prevent the two-way cross contamination of the material and heat exchange medium.
STRUCTURE DESCRIPTION OF SANITARY HEAT EXCHANGER
Structure Description of Sanitary Heat Exchanger
Double tubesheet structure:
This series of heat exchangers adopt double tubesheet structure design, so that the tube side and shell side are connected by their own tubesheet respectively, breaking the traditional of tube heat exchangers, where the tube side and shell side share the same connecting tubesheet, so as to minimize the risk of cross contamination, facilitate the timely discovery of potential leakage, and ensure the safe production of users.
Full emptying design:
the heat exchange tubes are 316L sanitary with smooth surface, straight structure, no dead corners, convenient and thorough cleaning, and the lowest point of the equipment is equipped with an emptying valve, which is conducive to the emptying of materials, cleaning water and condensate after online sterilization. The full emptying design avoids dead corners at the product contact parts, prevents the growth of microorganisms, and is easy to clean and sterilize.
Material and surface treatment:
this series of heat exchanger is made of 316L stainless steel, or the material required by customers. The roughness coefficient of the inner surface of the pipe in contact with the material is from 0.25 - 0.4 μ m.
OPERATING PRINCIPLES OF SANITARY HEAT EXCHANGER
FEATURES OF SANITARY HEAT EXCHANGER
1.
The heat exchange tube is made of 316L seamless steel pipe.
2.
Double tube sheet design eliminates cross contamination.
3.
The tubesheet is forged and the tubesheet thickness exceeds 10mm.
4.
There is no dead angle at the product contact side and it is completely drained.
5.
There is no dead space in the heat exchange channel.
6.
It can be installed vertically or horizontally.
7.
Product side quick installation interface, shell side flange connection.
8.
It can be designed and manufactured according to the special technical requirements of customers.
9.
Design and manufacture according to GMP requirements.
10.
Provide validation documents for double tube sheet heat exchanger.
APPLICATION OF SANITARY HEAT EXCHANGER
1.
Cooling/heating of water for injection.
2.
Sterilization of water for injection system by superheated water.
3.
Temperature rise and cooling of purified water.
4.
Pasteurization of purified water system.
5.
Pure steam condensation and cooling.
6.
Temperature control of highly clean liquid.
7.
Cooling/heating of liquid medicine.
8.
Cooling and heating of vaccines and blood products.
Biocell offers equipment and engineering system of generation, storage and distribution of purified water, water for injection, pure steam as well as ultra-pure water purification system pharmaceutical industry and also cosmetic and food & beverage industries.
Personne à contacter : .com biocell, 025 83192994
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de SANITARY HEAT EXCHANGER Rechercher dans la catégorie : Maroquinerie / Bagagerie Rechercher dans la catégorie : heat, sanitary, exchanger |
Dimanche 26 juillet 2015
We love what we do. No matter what section we deal in, we try our best to provide our customers the best quality products and services. We are very proud that the responses from our customers. We love nothing more than to hear from our customers and invite them to join us at any...
TRADEX GROUP CO LTD
- 15140 - opburi
- +6661409539
Mardi 31 mai 2016
Quantité : 270 - Prix : 8,85 €
- Avantages des luminaires LED OSRAM - - Qualité OSRAM - Produits LED de haute qualité pour les demandes exigeantes - Remplacement direct des luminaires conventionnels fluorescents ou halogènes - Le remplacement des luminaires standard permet jusqu'à 85 % d'économie d'énergie...
Samedi 13 juin 2015
Quantité : 100 - Prix : US$7.65
Description du produit: la fibre de céramique sont fabriqués à partir d'aiguilles punching couverture correspondant en céramique les fibres (com, st, hp, ha, hz). en utilisant les techniques de soufflage et de haute performance à ces produits offrent un supérieur performance isolante...
Zibo JC Eco-Tech Co., Ltd
- 255086 - China
- +86 15505335058
- +86 533 3593322