Chine (Rép. pop) Médical
Médical

PEEK Material Spinal Treatment Fusion Cage

PEEK Material Spinal Treatment Fusion Cage

Size Information

Product Code

Product Name

Specification

Material

441510002

Inter body fusion cage

ZJRH04

8x22

PEEK

441510004

8x26

441510007

8x32

441510009

8x36

441510022

10x22

441510024

10x26

441510027

10x32

441510029

10x36

441510042

12x22

441510044

12x26

441510047

12x32

441510049

12x36

441510062

14x22

441510064

14x26

441510067

14x32

441510069

14x36

PEEK spinal cages, also termed interbody fusion cages, are used in spinal fusion procedures to replace a damaged spinal disc and provide an ideal environment for two vertebrae to fuse together. PEEK interbody fusion cages are positioned between the two vertebrae that are to be fused.

▶▶ Product Description

Covex toothed surface design

An excellent fit to the anatomical structure of vertebral endplate

PEEK material

Closest to bone elastic modulus Radiolucent

Sufficient space for bone grafting

Improve the infusion rate

Bullet shape head

Easier implantation

Self-distraction during implantation

Three imaging marks

Easy for location under X-ray

▶▶ Medical Tips

What is TILF?

TLIF is a unilateral approach for interbody fusion to restore normal intervertebral space height and lumbar spine physiological lordosis. The TLIF technique was first reported by Harms in 1982. It is characterized by a posterior approach, which enters the spinal canal from one side. To achieve bilateral vertebral body fusion, there is no need to interfere with the central canal, which reduces the occurrence of cerebrospinal fluid leakage, does not need to stretch the nerve root and dural sac too much, and reduces the probability of nerve damage. The contralateral lamina and facet joints are preserved, the bone graft area is increased, 360° fusion is feasible, the supraspinous and interspinous ligaments are preserved, which can reconstruct the posterior tension band structure of the lumbar spine

What is PILF?

PLIF (posterior lumbar interbody fusion) is a surgical technique for fusing lumbar vertebrae by removing the intervertebral disc and replacing it with a (titanium) cage. The vertebrae are then stabilized by an internal fixator (transpedicular instrumented dorsal WK fusion). PLIF is a stiffening operation on the spine

In contrast to the ALIF (anterior lumbar intervertebral fusion), this operation is performed from the posterior, i.e. from the back. A surgical variant of the PLIF is the TLIF ("transforaminal lumbar interbody fusion").

How it works?

The cervical spine PEEK cages are very radiolucent, bio-inert, and are compatible with MRI. The cage will act as a space holder between the vertebrae affected, and then it allows the bone to grow and eventually becomes a part of the spine.

Indications

The indications may include: discogenic/facetogenic low back pain, neurogenic claudication, radiculopathy due to foraminal stenosis, lumbar degenerative spinal deformity including symptomatic spondylolisthesis and degenerative scoliosis.

Benefit

A solid cage fusion can eliminate the motion, increase the space for the nerve roots, stabilize the spine, restore spine alignment, and relieve pain.

▶▶ Material Of Fusion Cage

Polyetheretherketone (PEEK) is a non-absorbable biopolymer that has been used in a variety of industries including medical devices. The PEEK cages are biocompatible, radiolucent, and have modulus of elasticity similar to the bone.

Localisation : No.2, 16#, ChangXing Road, Development District, Zhangjiagang City, Jiangsu Province, China, 215600 Zhangjiagang City,
Personne à contacter : inature Tao, +86 13358048801

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
PEEK Material Spinal Treatment Fusion Cage

Rechercher dans la catégorie : Médical
Rechercher dans la catégorie :
fusion, peek, cage, spinal, material, treatment
Thailande 10110 Matières premières
Meilleur prix Scrap chaude cuivre de vente déchets métalliques / cuivre, ferraille fil...

Mardi 14 juillet 2015

Quantité : 15000MT - Prix : 2500euro

Meilleur prix Scrap chaude cuivre de vente déchets métalliques / cuivre, ferraille fil de cuivre, baie Copper Mill 99,9% ((Fabricant) Nous sommes des fournisseurs de haute qualité fil de cuivre Scrap 99,99% Milberry spécification Fil de cuivre SCRAP, (Millberry) 99,78% à une pureté de 99...)

CA PRODUCTS CO, LTD

  • 10110 - bangkok
  • +66 2 62 61 74 11
  • +66 9 62 91 74 69
France 467400 Pro / B2B
Des électrodes de graphite

Lundi 28 décembre 2015

Quantité : OEM/ODM Se - Prix : OEM/ODM Services

soutien d'électrodes en graphite graphite dans un cristal unique applicated champ thermique four. il est utilisé pour stabiliser les électrodes graphite graphite d'électrode en graphite de soutien zone chaude. la structure thermique four graphite cristal unique plus raisonnables,...

XRD Graphite Manufacturing Co., Ltd

  • zcxooo
  • 467400 - Pingdingshan
  • 86 15516002510
Taiwan 61355 Véhicule
Racing Brake Calipers YAR-F430-SB8pot

Jeudi 13 août 2015

The brake caliper YAR-F430-SB8pot is made of forging fluminum material and the color is available. Yar Jang is a professional brake calipers manufacturer in Taiwan and provides excellent quality and competitive price to meet customer's needs. If you have interested in our brake calipers...

Yar Jang Industrial Co.,Ltd.