Medical Equipment & Microbial-resistance Cable Jacket TPU
ATP's Medical Equipment and Microbial-resistance cable Jacket" passed ISO10993 "bio-compatibility" test (authoritative verification report attached );
Pass a series of comprehensive tests: resistance, microbial resistance, acid and alkali resistance, hydrolysis resistance (85℃&85%RH,1000Hrs) test;"
V0 grade material passed biological compatibility certification by Suzhou University; excellent resistance to hydrolysis, , chemical solvent, and low temperature; soft and smooth touch, matte surface; extrusion speed≥60M/min.
The polymer production for Wire for Medical Instruments markets.
Technical Data of Medical Equipment & Microbial-resistance Cable Jacket TPU
Technical Data Sheet |
Model |
Model |
||||
|
Material Properties |
Test Standard |
Test Condition |
Unit |
1182F-EMS-1219S |
1185D-ENB-1414S |
General Characteristics |
Material Category |
- |
- |
- |
|
|
Appearance(Light/Semi-matte/Frosted) |
- |
- |
|
|
|
|
Extrusion/Injection |
- |
- |
- |
|
|
|
Physical Characteristics |
Hardness |
ISO 48 |
15S |
Shore A |
84 |
85 |
Proportion |
ISO 1183 |
- |
g/cm³ |
1.083 |
1.185 |
|
Melt Index |
ISO 1133-1: 2011 |
190℃/2.16kg |
g/10min |
4.6 |
9.6 |
|
Brittle Temperature |
ISO 812 |
- |
℃ |
|
|
|
Mechanical Properties |
Elongation |
ISO37: 2017 |
200mm/min |
% |
465 |
492 |
Tensile Strength |
ISO37: 2017 |
200mm/min |
Mpa |
29.5 |
26.1 |
|
Tearing Strength |
ISO34-1: 2015 |
500mm/min |
KN/m |
|
|
|
Hot Air Aging |
Elongation Retention Rate |
ISO37: 2017 |
- |
% |
|
|
Tensile Strength Retention Rate |
ISO37: 2017 |
- |
% |
|
|
|
Electrical Performance |
Volume Resistivity |
ASTM D257 |
- |
Ohm-cm |
|
|
Permittivity |
ASTM D150 |
- |
- |
|
|
|
Combustion Performance |
Vertical Burning Test |
UL 94 |
3.0/6.0mm |
- |
|
|
Oxygen Index |
ASTM D2863 |
- |
% |
|
|
|
Feature |
|
As a professional polymer compound manufacturer, we provide tpe elastomer, atp material, antimicrobial tpu, tpu cable jacket and etc. For more information, please feel free to contact us!
Personne à contacter : Wang Daisy, 0769 38802055 894
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de Medical Equipment & Microbial-resistance Cable Jacket TPU Rechercher dans la catégorie : Divers Rechercher dans la catégorie : medical, microbial, jacket, equipment, cable, resistance |
Samedi 01 août 2015
ACAFA Full control PC under any OS, in BIOS mode, during boot, at Blue Screens Model: AI101P Single Port KVM over IP Description: The KVM over IP technology (IP-KVM) combines digital remote KVM access via IP networks with comprehensive and integrated system management. The IP-KVM...
ACAFA Information co,Ltd
- wendy2015
- 335000 - Taoyuan
- +88 6 33 07 13 00
Samedi 12 janvier 2013
Quantité : 1000 - Prix : 500,00 €
ISO 9001: 2000 Mantra Softech India Pvt. Ltd is prominent biometric fingerprint reader manufacturing organization in India. Company has been operating in biometric security sector for last 8 years in India. Mantra's biometric security solutions accommodates both time attendance solutions...
Mantra Softech India Pvt Ltd
- 380013 - Ahmedabad
- 9998848600
Mercredi 18 décembre 2024
Quantité : 500 - Prix : USD0.5/pc
100 years American Technology China Excellent Manufacturing Partner of Fortune top 500 A Leading Brand in Hose Clamp Industry Germany Type Hose clamp KEBG12X032 1)bandwidth:12mm 2)Thickness: 0.6mm 3)Material: W4 Stainless Steel 304ss 4)Diameter range: 20-32mm 5)These clamps...
King Seal Fastener Technology(Anhui) Co., Ltd.
- 233010 - Bengbu
- 86 552 4193229