Chine (Rép. pop) Biens d'équipement
Biens d'équipement

Hantek New MSO5000D Series On Offer

Quantité : 10   Prix : 100 000,00 €

Feature

  • 16 channels logic analyzer + 2 channels oscilloscope + external trigger.
  • Big and clear display (7.0-inch color LCD, high revolution 800 x 480), clear lifelike waveform display.
  • 1GSa/s real time sampling rate.
  • 60MHz-200MHz bandwidth, 1M memory depth.
  • Powerfultrigger function.
  • USB host, support flash memory card storage and USB interface system upgrade.
  • Ultrathin design, handy volume, easily portable.

* Oscilloscope Function

  • Bandwidth 60MHz-200MHz.
  • Each channel record length up to 1M.
  • Real time sampling rate up to 1GSa/s.
  • Powerfultrigger function.
  • More than 20 kinds of automatic measurement function.

* Logic Analyzer Function

  • 16 channels divided into 2 groups which is able to setup threshold level individually.
  • Real time sampling rate up to 500MSa/s.
  • Powerfultrigger function: edge, duration, pulse width, code-type, queen, repeat.

Specification

Oscilloscope Specification

Horizontal

Model

MSO5062D

MSO5102D

MSO5202D

Bandwidth

60MHz

100MHz

200MHz

SamplingRate Range

Max. 1GS/s

WaveformInterpolation

( sin x) /x

Memory Depth (Sample Points)

Single-channel: maximum 1M; Dual-channel: maximum 512K (4K, 16K, 40K optional)

SEC/DIV Range

8ns/div-40s/div (stepping in a sequence: 2,4,8)

Sampling Rate and Delay Time Accuracy

±50ppm in any ≥1ms time intervals

Delta Time Measurement Accuracy (full bandwidth)

Single, "sampling" mode

± (1 sampling interval + 100ppm × readings + 0.6 ns)

> 16 times above average

± (1 sampling interval + 100ppm × readings + 0.4 ns)

Sampling interval = SEC/DIV÷200

Vertical

A/D Converter

8-bit resolution, each channel sampled simultaneously

VOLTS/DIV Range

2mV/div ~ 5V/div at input BNC

PositionRange

±400mV (2mV/div ~20mV/div)

±2V (50mV/div ~200mV/div)

±40V (500mV/div ~2V/div)

±50V (5V/div)

Optional Analog Bandwidth Limit (typical)

20MHz

Low FrequencyResponse (-3db)

≤10Hz at output BNC

Rising Time at output BNC (typical)

60MHz

100MHz

200MHz

≤ 5.8ns

<3.5ns</p>

<1.8ns</p>

Vertical Gain Accuracy

±3% for sample or average acquisition mode, 5V/div to 10mV/div;

±4% for sample or average acquisition mode, 5mV/div to 2mV/div

DC Measurement Accuracy

Average Acquisition Mode

Measuring type: ≥16 zero vertical position waveform average .

Accuracy: ± (3%× reading+ 0.1div+ 1 mV), applicable to 10 mV/div or above units.

Measuring type: ≥16 non-zero vertical position waveform average.

Accuracy: ± [3%× (readings+ vertical position)+1%×vertical position+0.2div].

For the setting from 2mV/div to 200mV/div, +2mV; for 200mV/div to 5V/div, +50mV.

Voltage Measurement Repeatability

Average Acquisition Mode

In the same settings and environmental conditions, acquisition ≥ the voltage increment between any two groups average of 16 above waveforms : ± (3% × readings + 0.05 div)

Trigger

Trigger Sensitivity (Edge Trigger Type)

Coupling

Sensitivity

DC

Source

60MHz

100MHz

200MHz

CH1

CH2

1div from DC to 10MHz, 1.5div from 10MHz to Full

1.5div from 10MHz to 100MHz, 2div from 100MHz to Full

EXT

200mV from DC to 100MHz

200mV from DC to 100MHz, 350mV from 100MHz to 200MHz

EXT/5

1V from DC to 100MHz

1V from DC to 100MHz, 1.75V from 100MHz to 200MHz

AC

Attenuates signals below 10Hz

HF Reject

Attenuates signals when above 80kHz

LF Reject

The same as DC coupling limit when frequency above 150kHz; Attenuates signals when below 150kHz.

TriggerLevel Range

Source

Range

CH1, CH2

±8 divisions from center of screen

EXT

±1.2V

EXT/5

±6V

Trigger Level Accuracy, typical (Accuracy is for signals having rise and fall time ≥ 20ns)

Source

Accuracy

CH1, CH2

±(0.2div × V/div) (within ±4 divisions from center of screen)

EXT

±(6% of setting+40mV)

EXT/5

±(6% of setting+200mV)

Set Trigger Level to 50% (typical)

For the input signals ≥ 50Hz

Video Trigger Type

Source

Range

CH1, CH2

The amplitude of 2 points peak-peak

EXT

400mV

EXT/5

2V

Signal Format , Field Rate and Video Trigger Type

Any field or any line support NTSC PAL and SECAM

HoldoffRange

100ns-10s

Pulse Width Trigger

Mode

When <, >, =, or ≠ trigger; positive or negative pulses.

Trigger Point

: Triggers when pulse falling edge over trigger level.

≠: If the pulse narrower than the appointed width, the trigger point is the falling edge; or triggers when the pulse duration longer than the width setting time.

< : Triggers when the pulse duration less than the width setting time.

>(Also called overtime trigger): Triggers when pulse is greater than width setting.

Range

20ns ~10s

Slope Trigger

mode

When <, >, =, or ≠ trigger; positive or negative slopes.

Trigger Point

: Triggers when waveform slope is equal to slope setting.

≠: Triggers when waveform slope is not equal to slope setting.

<: Triggers when waveform slope is less than slope setting.</p>

>: Triggers when waveform slope is greater than slope setting.

Range

20ns-10s

Overtime Trigger

From the rising or falling edge; Setup time: 20-10 s

Alternative Trigger

CH1

Internal trigger: edge, pulse, video, or slop

CH2

Internal trigger: edge, pulse, video, or slop

Trigger Frequency Counter

Readout Resolution

6bit

Accuracy (typical)

±30ppm (Including all of the frequency reference error and ±1 calculation error)

FrequencyRange

AC coupling, from minimum 4Hz to specified bandwidth

Source

"Pulse width" or "edge trigger" mode: all available trigger source

"Frequency counter" is always measuringthe trigger source, even when oscilloscope acquisition paused because of the operation state's changing, or when a single acquisition finished.

The “pulse width" trigger mode: the oscilloscope calculates the pulses whose window having effective amplitude, which measure at 1s and meet trigger condition. For example, if the PWM pulse line is set to < mode, and width is correspondingly set to smaller time, then the narrow pulse among them is the one to be calculated.

"Edge trigger" mode: the oscilloscope calculates all the edge with sufficient amplitude and correct polarity.

"Video trigger" mode: "frequency counter" doesn't work.

Acquisition

Mode

Sample, Peak value detection and Average

SINGLE SEQ

Acquisition Mode

Acquisition Stop Time

Sample, peak value detect

All communications start to single acquisition simultaneously

Average

All communications start to N times acquisition simultaneously, and N could be 4, 8, 16, 32, 64 or 128

Input

Input Coupling

DC, AC or GND

Input Impedance, DC Coupling

1MΩ±2% for 20pF±3 pF

Probe Attenuation

1X, 10X

Support Probe Attenuation Coefficients

1X, 10X, 100X, 1000X

Max. Input Voltage

Overvoltage Type

Max. Voltage

CAT I and CAT II

Installation type: 300VRMS(10×)

CAT III

150VRMS(1×)

Installationtype Ⅱ: Take 20 dB/decade as slope, from 100kHz above begins to decline to ≥ 3MHz *, the AC peak value is 13V. For the non-sine waveforms, the peak value must less than 450V. Above 300V the offset duration should be less than 100ms. RMS signal level (including all the DC component delete by the AC coupling) must be limited to 300V. If beyond these values, it may damage the device.

Measurement

Cursors

The difference between voltage cursors △V; the difference between time cursors △T; 1/△T calculated by Hz.

Automatic

Frequency, Period, Mean, Pk-Pk, Cyc RMS, Min, Max, Rise Time, Fall Time, Positive Width, Negative Width.

General

Display

Type

7” TFT, 64K true color LCD

Resolution

800x480 dots

Contrast

16 gears with the progress bar to show adjustment

Probe Compensator Output

Output Voltage (typical)

About 5Vpp input ≥ 1 M Ω load

Frequency (typical)

1kHz

Power Supply

Voltage

100-120VACRMS(±10%),45Hz to 440Hz, CATⅡ

120-240VACRMS(±10%),45Hz to 66Hz, CATⅡ

Power

< 30W

Fuse

2A, T rating, 250V

Environment

Temperature

Working: 32℉to 122℉ (0℃ to 50℃)

Not working: -40℉ to 159.8℉ (-40℃ to +71℃)

Cooling Type

Convection

Humidity

+ 104 ℉ or below (+ 40 ℃ or below) : ≤90% relative humidity

+ 106 ℉ to 122℉ (+ 40 ℃ to 50℃) : ≤60% relative humidity

Sea Level Height

Working and Not working

3,000m (10,000 foot)

Random Vibration

50Hz to 500 Hz: 0.31 g RMS, each axial: 10 minutes

Not working

5Hz to 500 Hz: 2.46 g RMS, each axial: 10 minutes

Mechanical Shock

Working

50g, 11ms, half-sine wave

Mechanical

Dimension

Length

313mm

Height

142mm

Thickness

108mm

Weight

Not including the weight of package and accessories

2.08Kg

Packing Dimension

Length

395mm

Width

410mm

Height

275mm

Gross Weight

Including all accessories

about 3.2kg

Logic Analyzer Specification

Sampled Channels

16 ( divided into 2 groups)

Max. Input Impedance

200K (C=10p)

InputVoltage Range

-60V~60V

LogicThreshold Range

-8V~8V

Max. Sample Rate

500MHz

Compatible Input

TTL, CMOS, ECL

Sample Depth

512KSample

Cursors

The difference between voltage cursors △V; the difference between time cursors △T; 1/△T calculated by Hz.

Measurement

Period and Frequency

Record Position

RefA

RefB

Trigger

Edge

D0-D15 select slope (rising or falling edge)

Pulse Width

D0-D15 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, <), trigger pulse width</p>

Code-type

D0-D15 select code-type (H, L, X)

Duration

D0-D15 select persist time and trigger when (data terminate, data start, and data delay)

Queue

D0-D15 select specific data index (0-3) and code-type (H, L, X)

Repeat

D0-D15 select code-type (H, L, X) and repeat times

Localisation : 5/F, No. 177 Zhuzhou Road, 266101 Qingdao,
Personne à contacter : Rose Wang, +86 532 88703687

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
Hantek New MSO5000D Series On Offer

Rechercher dans la catégorie : Biens d'équipement
Rechercher dans la catégorie :
series, hantek, offer, mso5000d
Annonce GOLD
France 22440 Destockage
Offre exceptionnelle : Lot de 1000 réfrigérateurs americain Samsung RS68CG882ES9 à prix...
Verified

Jeudi 21 novembre 2024

réfrigérateurs americain Samsung

Quantité : 1000 - Prix : 590,00 €

Offre exceptionnelle : Lot de 1000 réfrigérateurs américains Samsung RS68CG882ES9 à prix déstockage ! Saisissez cette opportunité unique avec un lot de 1000 réfrigérateurs américains Samsung RS 68 CG 88 2E S9 à un prix de déstockage exceptionnel de 590 €/unité par 500 unités. Ce modèle haut de gamme est parfait pour les grossistes cherchant à proposer à leurs clients un produit combinant design élégant, technologie avancée, et performance énergétique. Caractéristiques principales...

TRANSIDI

  • 22440 - PLOUFRAGAN
  • 02 30 96 63 26
  • 33(0)603670505
Danemark 9240 Recherche / Achat
UC Headset

Samedi 15 mai 2021

As a professional telephone addasound headset supplier, we offer addasound products which are specially designed for professional users in call centers and offices who would like to have the best hands-free device while experiencing superior noise-canceling, crystal clear voice transmission...

ADDASOUND DENMARK A/S

  • 9240 - Denmark
  • 45 72 628 628
France 528000 Matières premières
316 Stainless Steel Sheet

Mardi 27 février 2024

Prix : 10000-40000 RMB/MT

Normandy Metal, your reliable source for 316 stainless steel sheet metal. We offer a wide range of 316 stainless steel plates, known for their superior corrosion resistance, especially against chlorides and other industrial solvents. Whether you're looking for a polished 316 stainless...

Normandy Metal Industry Co., Ltd.