GC-9801 Gas Chromatography
Quantité : 100000000 Prix : 100 000 000,00 €
http://www.shieldlance.com/
Product Description
Gas Chromatography
Gas Chromatography is used to separate organic solvents, can test solvent residues of printed packaging material, or the purity of a single solvent.
Working Principle
Gas sample of mixed solvents is carried by N2 to pass through and separated by chromatographic column, transformed to signal and detected by sensor, then the system can identify the solvents one by one and make qualitative and quantitative analysis of each solvent. Solvent residues test unit is “mg/m2“, purity test unit is “%”.
Standards
QBT 2929, GB/T 10004-2008, YBB 00132002
Features
- Can adjust pressures; multiple gas pipelines of N2, H2, air, exhaust, splitting, cleaning.
- LCD display temperatures.
- Integrated design, easy to install and maintain.
- Excellent noise reduction, working quiet.
- Over temperature protection.
- With data work station, powerful data analysis.
- Professional software, fully functional, multiple parameters setting and test.
- Can zoom and move chromatogram curve freely.
- Professional test report, can export file in PDF format etc.
- Manual press button switch, function is the same as “Acquire Data” command button in software interface, convenient for operation.
- Simple calibration of baseline and sensor.
Specifications
| Detector | Hydrogen flame ionization detector (FID) (other detectors optional) |
| Sensitivity | Mt≤1×10-11g/s (palmityl) |
| Baseline shift | ≤0.02mv/h |
| Noise | ≤0.02mv |
| Chromatographic column | OV-1701 capillary chromatographic column, 50m*0.32mm*0.5um, max. temp. 280℃(other types of chromatographic column optional) |
| Sample injection port | capillary column port (other types optional) |
| Column box size | 240×210×240mm |
| Temperature range | maximum 400℃ |
| Temperature precision | 0.1% |
| Temperature resolution | 0.1℃ |
| Temperature rise speed | 0~40℃/minute |
| Carrier gas | N2, 99.99%, 0.4Mpa, dry |
| H2 source | 99.99%, 0.4Mpa, dry |
| Air source | 0.4Mpa, dry, clean, no oil |
| Gas port | Φ3mm gas pipe |
| Instrument size | 46×43×43cm |
Configuration
Gas Chromatography, chromatographic column, data work station, software, communication cable, power cable, desiccant devices 3pcs, syringes 8pcs, sample bottles 50pcs, bottle caps (aluminum shell and rubber plug) 150 sets, sealing plier, gas , installation fittings, spanner
Optional: thermal conductivity detector (TCD), electronic capture detector (ECD), flame photometric detector (FPD), nitrogen and phosphor detector (NPD)
User provide: N2, H2, air
Personne à contacter : Yunlong Li, 0086 20 82209969
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
|
Cette page concerne les importateurs et exportateurs de GC-9801 Gas Chromatography Rechercher dans la catégorie : Décoration / Objets Rechercher dans la catégorie : chromatography |
Thursday 13 January 2022
France Vision Distribution spécialiste de l'import / export, déstockage et produits High-tech. Nous proposons une large gamme de produits a forte demande, contactez nous et visitez notre site internet pour plus d'informations. Site : www.france-vision-distribution.com Téléphone :...
France Vision Distribution
- 75015 - Paris
- 09 74 55 07 59
Thursday 30 June 2022
Quantité : 100
La gamme S3300 rassemble une nouvelle génération de smart switches Web manageables stackables Gigabit dotés de 4 ports 10 Gigabit, pouvant être utilisés pour des liaisons montantes et/ou dans un stack avec d'autres switches S3300. Le stack mixte avec une sélection de switches 10 Gigabit...
MaKant Europe GmbH & Co. KG
- 60386 - Frankfurt am Main
- +49 (69) 9 150 750 14
Saturday 06 May 2023
Reliability, Reliability, and Reliability. This is what all maintenance teams will focus on in the chemical plants, reliability can be easily obtained through EAMic® CMMS: System embedded failure analysis report, ultra red and vibration pen (equipment temperature and vibration data...)
- 200030 - shanghai
- 021 6958 0696
Paiement sécurisé