CZ3000 Temperature Converter Signal Conditioner
Quantité : 1 million Prix : 200-2000 CNY/pc
CZ3000 Temperature Signal Conditioner
Thermal resistance type signal isolators, the two-wire or three-wire system resistance signal is converted into 0/4~20mA current signal isolation or 0/1~5V voltage signal output. It is intelligent, can through the computer scope of heat resistance index number range and configuration.
This 5v to 24v signal converter should be supplied power independently. Input circuit, output circuit and power supply are each galvanically isolated.
Advantages of CZ3000 Temperature Converter Signal Conditioner
24V DC independent/ loop power supply
Line fault detection(LFD)
Configurable by software
Integral CJC on terminals/TC input terminals
Parameter of CZ3000 Temperature Converter Signal Conditioner
|
CZ3076 |
CZ3079 |
|
CZ3071 |
1/2 |
2/2 |
|
1/1 |
|
|
|
Input Signal |
Pt100,Cu100,Cu50 |
Pt100,Cu100,Cu50 |
Pt100,Cu100,Cu50 |
Output Current/Load Resistance |
0~20mA,4~20mA / RL ≤300Ω |
0~20mA,4~20mA / RL ≤300Ω |
0~20mA,4~20mA / RL ≤300Ω |
Output Voltage/Load Resistance |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
Fault Current of Overrange/Underrange |
IH≈20.8mA/IL≈3.8mA |
IH≈20.8mA/IL≈3.8mA |
IH≈20.8mA/IL≈3.8mA |
Fault Current of Line Break |
I≈20.8mA |
I≈20.8mA |
I≈20.8mA |
Supply Voltage |
20~35V DC |
20~35V DC |
20~35V DC |
Power Reverse Protection |
Support |
Support |
Support |
Current Consumption(Supply voltage: 24V) |
≤35mA |
≤55mA |
≤55mA |
Temperature Drift |
0.01%F.S./℃ |
0.01%F.S./℃ |
0.01%F.S./℃ |
Response Time (0~90%) |
≤1s |
≤1s |
≤1s |
Dielectric Strength |
1500V AC;1min |
1500V AC;1min |
1500V AC;1min |
Insulation Resistance |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
EMC Standards |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
Suitable Field Apparatus |
2-or 3-wire RTD |
2-or 3-wire RTD |
2-or 3-wire RTD |
|
|
|
|
|
CZ3072 |
CZ3074 |
CZ3079.TC |
1/1 |
1/2 |
2/2 |
|
Input Signal(Customized mV signal) |
T、E、J、K、N、R、S、B |
T、E、J、K、N、R、S、B |
T、E、J、K、N、R、S、B |
Internal CJC Temperature Range |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
CJC Precision |
±1℃ |
±1℃ |
±1℃ |
Output Current/Load Resistance |
0~20mA,4~20mA / RL≤300Ω |
0~20mA,4~20mA / RL≤300Ω |
0~20mA,4~20mA / RL≤300Ω |
Output Voltage/Load Resistance |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
Fault Current of Overrange/Underrange |
IH≈20.8mA/IL ≈3.8mA |
IH≈20.8mA/IL ≈3.8mA |
IH≈20.8mA/IL ≈3.8mA |
Fault Current of Line Break |
I≈20.8mA |
I≈20.8mA |
I≈20.8mA |
Supply Voltage |
20~35V DC |
20~35V DC |
20~35V DC |
Power Reverse Protection |
Support |
Support |
Support |
Current Consumption(Supply voltage: 24V) |
≤35mA |
≤55mA |
≤55mA |
Temperature Drift |
0.01%F.S./℃ |
0.01%F.S./℃ |
0.01%F.S./℃ |
Response Time (0~90%) |
≤1s |
≤1s |
≤1s |
Dielectric Strength |
1500V AC;1min |
1500V AC;1min |
1500V AC;1min |
Insulation Resistance |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
EMC Standards |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
Suitable Field Apparatus |
TC and mV signal sensor |
TC and mV signal sensor |
TC and mV signal sensor |
|
|
|
|
|
1/1:CZ3077 |
1/1:CZ3177 |
1/1:CZ3277 |
2/2:CZ3078 |
2/2:CZ3178 |
2/2:CZ3278 |
|
Input Signal |
Pt100,Cu100,Cu50 |
T、E、J、K、N、R、S、B |
Pt100,Cu100,Cu50 |
(Customized mV signal) |
T、E、J、K、N、R、S、B |
||
Internal CJC Temperature Range |
|
-20~+60℃ |
-20~+60℃ |
CJC Precision |
|
±1℃ |
±1℃ |
Output Current |
4~20mA |
4~20mA |
4~20mA |
Load Resistance |
RL ≤(Ue -12)/0.021Ω |
RL ≤(Ue -12)/0.021Ω |
RL ≤(Ue -12)/0.021Ω |
Fault Current of Overrange/Underrange |
IL ≈20.8mA/IL ≈3.8mA |
IL ≈20.8mA/IL ≈3.8mA |
IL ≈20.8mA/IL ≈3.8mA |
Fault Current of Line Break |
I≈20.8mA |
I≈20.8mA |
I≈20.8mA |
Loop Supply Voltage(Ue) |
12~30V DC |
12~30V DC |
12~30V DC |
Power Reverse Protection |
Support |
Support |
Support |
Temperature Drift |
0.01%F.S./℃ |
0.01%F.S./℃ |
0.01%F.S./℃ |
Response Time (0~90%) |
≤1s |
≤1s |
≤1s |
Dielectric Strength |
1500V AC;1min |
1500V AC;1min |
1500V AC;1min |
Insulation Resistance |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
EMC Standards |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
Suitable Field Apparatus |
2-or 3-wire RTD |
TC sensor,mV signal |
RTD,TC sensor |
Signal conditioners are electrical devices, which are connected between the industrial field instrument and the control room. CHENZHU's signal conditioner complete in specifications.
Personne à contacter : Danping Li, 021 6451 3350
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de CZ3000 Temperature Converter Signal Conditioner Rechercher dans la catégorie : Biens d'équipement Rechercher dans la catégorie : temperature, converter, signal, conditioner, cz3000 |
Jeudi 19 décembre 2024
Prix : 650usd
Nous déclarons que nous sommes prêts, disposés en mesure de fournir et vendre de grade «A» Pieds de poulet transformés . Nous avons une certaine quantité raisonnable du produit à vendre . Voici les détails de notre produit de notre usine et nos conditions de vente : Produit : Pieds...
setecstra
- 843 - abidjan
- +22 5 49 87 56 63
- +225 04619689/498756
Jeudi 17 décembre 2015
Quantité : 5000 tons - Prix : 85EUR per ton
Nous sommes fabricant direct et principal fournisseur de la norme européenne de granules de bois 6mm, 8mm avec la teneur en humidité: <</span>7% et la valeur calorifique: <</span>4.7kWh / kg. CARACTÉRISTIQUES de granulés de bois: 1. Application: Maison Chauffage 2...
TRANSPORTES APICHE,S.L.
- 02400 - Albacete
- 961827882
Dimanche 29 mai 2016
Quantité : 200 - Prix : 6,35 €
- Avantages des luminaires LED OSRAM - - Qualité OSRAM - Produits LED de haute qualité pour les demandes exigeantes - Remplacement direct des luminaires conventionnels fluorescents ou halogènes - Le remplacement des luminaires standard permet jusqu'à 85 % d'économie d'énergie...