CUCW-N142 Unitized Curtain Wall
Model No. CUCW-N142 is a self-designed, tested, and certificated unitized curtain walling system by CAS team. It is a cost efficient and performance unitised curtain wall system, which combines minimal aesthetics with structural stability. Its structural silicone glazing construction offers maximum transparency at the external surface of the facade. Modular units, including glazing panes, are prefabricated in workshop conditions and this results in a fast and economic installation with minimum manpower and tooling requirements. This construction mode, renders CUCW-N142 an ideal unitised system for high rise buildings,where meeting demanding deadlines is a prerequisite.
Overview of CUCW-N142 Unitized Curtain Wall
System |
Unitized Curtain Wall(Non-Thermal Break) |
Model No. |
CUCW-N142 |
Material |
Aluminum Alloy/Glass/Aluminum Sheet/Aluminum Composite Panel/Galvanized Sheet |
Glass Type |
Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak |
Cooperated Glass Brand |
Vitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/King/CNG/Ta iwanGlass |
Surface Treatment |
Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain |
Profile Brand |
6063-T5/6063-T6/6061-T6(Brackets) |
Thermal Profile |
Non-Thermal Break |
Standards |
In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO |
Application |
Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization |
System Customziation |
Available |
Data of CUCW-N142 Unitized Curtain Wall
Testing Data of CUCW-N142 Unitized Curtain Wall
Test |
Pressure |
Results |
Preloading(Clause 8.2.2 of AS/NZS4284: 2008) |
+1.46kpa |
No separation, plastic deformations, or deleteriousness was observed. |
-1.90kpa |
||
Preliminary Water Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284: 2008) |
+438kPa |
There were no leaks. |
Preliminary Water Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284: 2008) |
219-438-219 (Pa) |
There were no leaks. |
292-584-292 (Pa) |
||
438-876-438 (Pa) |
||
Structural Test at Serviceability Limit State Wind Pressure (Walls)(Clause 8.3 of AS/NZS 4284: 2008) |
+1.46kpa |
During the structural test at SLS wind pressure, the deflections of all related members were within the allowable deflection limits. |
-1.90kpa |
||
Air Infiltration Test (Clause 8.4 of AS/NZS 4284: 2008) |
+/-150Pa |
The rate of air leakage of the specimen was within the allowable values. |
Water Test under Static Water Test under Static 4284: 2008) |
+438Pa |
There were no leaks. |
Water Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284: 2008) |
219-438-219 (Pa) |
There were no leaks. |
292-584-292 (Pa) |
||
438-876-438 (Pa) |
||
Structural ProofTest at Ultimate Limit State Wind Pressure (Wells) (Clause 8.8 of AS/NZS 4284: 2008) |
+2.26kpa |
No collapse of the test specimen was observed under the specified pressure. |
-2.94kpa |
||
Seal Degradation Test(Clause 8.10 of AS/NZS 4284: 2008) |
219-438-219 (Pa) |
No water leakage was observed. |
292-584-292 (Pa) |
||
438-876-438 (Pa) |
Thermal Data of CUCW-N142 Unitized Curtain Wall
NFRC Procedures |
NFRC100SB, NFRC200-2010, and NFRC500-2010 |
Software Tools |
THERM 7.4.3.0 and WINDOW 7.4.6.0 |
Configuration |
6 CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU |
Panel Dimension |
1505mm Wide 2945mm High |
Frame |
Painted Aluminum |
Panel U-value |
2.765W/m2k |
Visible Light Transmission |
0.246 |
SHGC |
0.179 |
Frame Data of CUCW-N142 Unitized Curtain Wall
Parts Location |
Frame Area/m2 |
Edge Area/m2 |
U-Value(Frame) |
U-Value(Edge) |
W/m2k |
W/m2k |
|||
Header |
0.058 |
0.086 |
4.1858 |
1.1968 |
Left Jamb |
0.127 |
0.166 |
14.8377 |
1.6873 |
Right Jamb |
0.127 |
0.166 |
23.7685 |
1.9897 |
Sill |
0.328 |
0.086 |
5.7542 |
1.5668 |
Glass Data of CUCW-N142 Unitized Curtain Wall Manufacture
Glass Data: CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU |
|||||||
Visible Light |
SHGC |
SC |
NFRC U-value |
STC |
|||
W/m3k(Argon) |
|||||||
T% |
R-out% |
R-in% |
Winter |
Summer |
|||
29 |
19 |
15 |
0.19 |
0.22 |
1.55 |
1.54 |
36 |
Benefit of CUCW-N142 Unitized Custom Curtain Wall
Guaranteed waterproofness & airtightness
Great quality control from factory
Lower on-site installation cost
Shorter project schedule
Enhancement of natural light
Increased static robustness, even in extreme natural phenomena
Minimum after sales service & maintaining
Increased comfort level
If you want to know more details of unitised system facade, please visit our website.
Personne à contacter : facade Cas, 0757 87655056
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de CUCW-N142 Unitized Curtain Wall Rechercher dans la catégorie : Divers Rechercher dans la catégorie : curtain, n142, cucw, wall, unitized |
Samedi 20 février 2016
Quantité : 100 MT PER - Prix : 2000 usd per mt CIF
Hemp seeds Product Name: Hemp seed extract Latin Name: Cannabis sativa L Appearance: Brown yellow powder Part used: Seed Application: Health-care products Shelf Life: 24(month) Name Hemp Seed Botanical source Cannabis sativa L. Specification 3.5mm belwo,3.5-5.0mm...
Khun Jack Partnership Ltd
- 5000 - Chaing Mai
- +66 9 68 75 20 43
Mercredi 14 septembre 2016
Quantité : 5000 - Prix : 50,00 €
Robinet à soupape PN 16/25/40 Acier moulé - Robinet à soupape PN 25‑40 - Construction suivant DIN 3356 - Diamètre : DN15 à DN300 - Chapeau boulonné à arcade - Presse-étoupe boulonné - Tige montante à filetage extérieur - Ecartement suivant EN 558‑1 Série 1 - Raccordement...
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935
Jeudi 15 novembre 2007
WSC SARL Contact : Velizar Todorov (Mr) Tel : 00352 22 9999 5523 Mobile : 00352 661 655565 Fax : 00352 22 9999 5499 Luxembourg Lot de Barrières autoalimentées, télécommandées, pour protéger un parking privé ou empêcher le passage vers une voie d'accès privée. Prévue pour les emplacements...
Paiement sécurisé