Chine (Rép. pop) Médical
Médical

CTnI test kit (FIA) CE Marked

Product Name
Troponin I (cTnI) Test Kit (Immunofluorescence Chromatography)

Purpose
To detect the cTnI in human plasma/serum/whole blood in vitro quantitatively.For Professional Use only.

Principles of Detection
The cTnI Test is a fluorescent lateral flow immunoassay. The test consists of: 1) a conjugate pad containing cTnI antibody conjugated with fluorescent microspheres and a control antibody (goat anti-chicken IgY antibody) conjugated with fluorescence microspheres, 2) a nitrocellulose membrane strip containing a test line (T line) and a control line (C line). The T line is pre-coated with another cTnI antibody, and the C line is pre-coated with a control line antibody (chicken IgY antibody).
cTnI concentration in specimen is positively correlated with the fluorescent density of the microspheres, after the measure and calculation of the quantitative fluorescence immunoassay analyzer, then the analyzer would calculate the concentration of cTnI according to the preset calibration curve in the machine and display the result, detection unit is ng/mL. C line should appear in any cases, which indicates the reaction system is effective.

Storage conditions and shelf life
Store in a sealed aluminum foil bag at 2~30°C. After unpacking the aluminum foil bag under temperature 20~30 ºC , humidity 35~65%, please use it immediately.
Shelf life 18 months.

Applicable instrument
Avid fluorescent immunoanalyzer model: AI-IF 600

Reference range
The 95th percentile of the serum and plasma samples of 200 normal persons is <0.3ng/mL.;<br /> The reference value is verified by referring to similar products on the market. Due to ethnic and regional differences, each laboratory can establish its own reference interval according to the actual situation.

Performance Characteristics
1. Linear range
In the range of 0.1ng/mL ~40ng/mL, the r value should be ≥0.990.
2. Accuracy
Detected with the enterprise internal control accuracy reference (C1, C2), the test results should be within the following ranges.
(1) Detection with the enterprise internal control accuracy reference C1, the instrument measurement range is 0.5ng/mL ±15% at 15 minutes.
(2) Detection with the enterprise internal control accuracy reference C2, the instrument measurement range is 5ng/mL ±15% at 15 minutes..
3. Intra-batch precision
Using the enterprise internal control precision reference (C9, C10) each parallel test 10 times, at 15 minutes instrumentation, the concentration value coefficient of variation CV≤15%.
4.Inter-batch precision
For three batches of reagent kits, 10 times of parallel testing with each enterprise internal control precision reference (C9, C10), and the instrument measurement at 15 minutes, the concentration coefficient of variation CV≤15%.
5.Detection limit
Detection with the enterprise internal control of the detection limit reference L1, instrumentation at 15 minutes, the results should be ≤0.1ng/mL.
6.Specificity
Detection with the enterprise internal control specificity reference (C3, C4, C5), the instrument measurement value at 15 minutes should be less than 0.1ng/mL.

Localisation : C501, Bui Iding B5, China Merchants Guangming Science Park,#3009 Guanguang Road,Guangming District, Shenzhen, 518132 Shenzhen,
Personne à contacter : Yang Shawn, +8618543132823

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
CTnI test kit (FIA) CE Marked

Rechercher dans la catégorie : Médical
Rechercher dans la catégorie :
test, ctni, marked
Surface Grinder -Sunny Machinery Co., Ltd.

Thursday 07 August 2014

Established in 1980, Sunny Machinery has been focusing in the pursuit of continuous quality improvement and perfection. Its "Freeport" surface grinders are dearly entrusted and acclaimed among numerous satisfied clients, and guide Sunny Machinery to become a major multinational exporting...

S&J

  • 407 - Taichung , Taiwan
  • 886437038989
Jawo Sheng Precise Machinery Works Co., Ltd.

Friday 13 November 2015

Jawo Sheng Precise Machinery Works Co., Ltd. Founded in 1978, JS have manufactured embossing machine, varnishing machine, flexo printing machine, flexographic printing machine and packaging printing machine over years. Therefore, we have been at the forefront of the industry for...

Jawo Sheng Precise Machinery Works Co., Ltd.

  • Sj1978
  • 414 - Taichung
  • +886 4 2335 8268
  • +886423358268
FP-100 Tabletop Piston Liquid Filling Machine

Thursday 10 July 2025

Tabletop Piston Liquid Filling Machine FP-100 is the best candidate with the consideration of budget. The volumetric piston filler draws liquids and other low viscosity products such as oils or juices directly from a tank or drum It is the simple design, low failure rate and fully...

Autopack Co.,Ltd