Chine (Rép. pop) Médical
Médical

CTnI test kit (FIA) CE Marked

Product Name
Troponin I (cTnI) Test Kit (Immunofluorescence Chromatography)

Purpose
To detect the cTnI in human plasma/serum/whole blood in vitro quantitatively.For Professional Use only.

Principles of Detection
The cTnI Test is a fluorescent lateral flow immunoassay. The test consists of: 1) a conjugate pad containing cTnI antibody conjugated with fluorescent microspheres and a control antibody (goat anti-chicken IgY antibody) conjugated with fluorescence microspheres, 2) a nitrocellulose membrane strip containing a test line (T line) and a control line (C line). The T line is pre-coated with another cTnI antibody, and the C line is pre-coated with a control line antibody (chicken IgY antibody).
cTnI concentration in specimen is positively correlated with the fluorescent density of the microspheres, after the measure and calculation of the quantitative fluorescence immunoassay analyzer, then the analyzer would calculate the concentration of cTnI according to the preset calibration curve in the machine and display the result, detection unit is ng/mL. C line should appear in any cases, which indicates the reaction system is effective.

Storage conditions and shelf life
Store in a sealed aluminum foil bag at 2~30°C. After unpacking the aluminum foil bag under temperature 20~30 ºC , humidity 35~65%, please use it immediately.
Shelf life 18 months.

Applicable instrument
Avid fluorescent immunoanalyzer model: AI-IF 600

Reference range
The 95th percentile of the serum and plasma samples of 200 normal persons is <0.3ng/mL.;<br /> The reference value is verified by referring to similar products on the market. Due to ethnic and regional differences, each laboratory can establish its own reference interval according to the actual situation.

Performance Characteristics
1. Linear range
In the range of 0.1ng/mL ~40ng/mL, the r value should be ≥0.990.
2. Accuracy
Detected with the enterprise internal control accuracy reference (C1, C2), the test results should be within the following ranges.
(1) Detection with the enterprise internal control accuracy reference C1, the instrument measurement range is 0.5ng/mL ±15% at 15 minutes.
(2) Detection with the enterprise internal control accuracy reference C2, the instrument measurement range is 5ng/mL ±15% at 15 minutes..
3. Intra-batch precision
Using the enterprise internal control precision reference (C9, C10) each parallel test 10 times, at 15 minutes instrumentation, the concentration value coefficient of variation CV≤15%.
4.Inter-batch precision
For three batches of reagent kits, 10 times of parallel testing with each enterprise internal control precision reference (C9, C10), and the instrument measurement at 15 minutes, the concentration coefficient of variation CV≤15%.
5.Detection limit
Detection with the enterprise internal control of the detection limit reference L1, instrumentation at 15 minutes, the results should be ≤0.1ng/mL.
6.Specificity
Detection with the enterprise internal control specificity reference (C3, C4, C5), the instrument measurement value at 15 minutes should be less than 0.1ng/mL.

Localisation : C501, Bui Iding B5, China Merchants Guangming Science Park,#3009 Guanguang Road,Guangming District, Shenzhen, 518132 Shenzhen,
Personne à contacter : Yang Shawn, +8618543132823

Bonne affaire : acheter au vendeur

Consultez notre guide pour effectuer une transaction en toute sécurité ! En aucun cas Algomtl ne peut être tenu responsable des annonces publiées. Seule la responsabilité du vendeur ou de l'acheteur en cas de litige est engagée.
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de
CTnI test kit (FIA) CE Marked

Rechercher dans la catégorie : Médical
Rechercher dans la catégorie :
test, ctni, marked
Hong Kong 523929 Biens d'équipement
China Rooman Home Air Purifier AC300

Vendredi 14 août 2015

Quantité : 200 at lea - Prix : To be discussed

Key Specification: - Color: Various color can be chosed - Input Voltage: 120~240V - Rated Power: 50-60HZ - Power (W): 36~55W - Noise Level: 25~55dB - Display Mode:LED - Control Mode: Touch screen - CADR: 320m³/H - Purifying Rate: 99.7% - Length Of Power Cord: 2...

Rooman Electrical Appliances Co., Ltd.

  • Rooman1
  • 523929 - Dongguan
  • +13 6 62 88 32 70
Indonésie 20152 Véhicule
2015 Scott Spark 700 SL Mountain Bike

Jeudi 02 avril 2015

SPECIFICATION : Frame Spark Carbon / IMP technology / HMX / BB92 / Carbon swingarm with 160PM U-Mono Link / Tapered Headtube IDS SL dropouts for 142 × 12mm BB height adj. Travel Front 120mm Rear 120 - 85 - Climb / Shock 190 × 50 Fork FOX 32 Float Factory CTD Air / Kashima...

INDOBIKESPORT

  • 20152 - Medan - Sumatera Utara
  • +628994498351
Taiwan 80673 High Tech
PICOTEST G5110A 15MHz Function/Arbitrary Waveform Genertor - Better than Agilent 33210A

Mercredi 26 novembre 2014

Quantité : 1 piece - Prix : USD 348

This model, G5110A, has G5100A's features of providing Sine, Square, Arbitrary, Ramp, Pulse, DC, Exponential Rise & Fall, Negative Ramp, Sin(x)/x, and Cardiac waveforms, supporting vital modulations, such as AM, FM, PM, PWM, FSK, Sweep, and Burst, and enabling the amplitude range...

PICOTEST CORP.

  • n800097
  • 80673 - Kaoshiung
  • 886 7 815 7183 ext : 806
  • 886 920 032 030