Carymart
12 Channel 6000ft Long Range NO /NC 12 Control Modes Wireless Remote Control System
Application: It can be used in industry automation, agriculture automation and home automation, such as factory, house, farm, pasture, vehicle, ship, offshore operation, aerial vehicle, field call, etc. It can remote control equipments on land, water and air, such as remote control lights, sirens, locks, motors, fans, winches, blinds, linear actuators, doors, windows, electric solenoid valves, security alarm, business signs and various devices.
Wireless control, easy to install.
Relay Output: This receiver is relay output, it can be used to operate both DC and AC equipments. The terminals are NO / NC (normally open / normally closed), which serves as a switch. That means you should also connect a separate power supply to equipments.
You can turn on/ off the receiver with transmitter (remote control) from any place within a reliable distance.
Wireless RF signal can pass through walls, floors, doors or windows.
With reverse power protection and over current protection.
Reliable control: The receiver only works with the transmitter which use same code.
One/several transmitters can control one/several receivers simultaneously.
You can use two or more units in the same place.
Receiver Parameters:
Model No.: S12CA-DC09-ANT2 / S12CA-DC12-ANT2 / S12CA-DC24-ANT2
Power Supply (Operating Voltage): DC12V±1V (S12CA-DC12-ANT2), DC9V±1V (S12CA-DC09-ANT2), DC24V±1V (S12CA-DC24-ANT2)
Output: Relay output (Normally open and normally closed)
Working Voltage Range of Relay: AC110~240V or DC0~28V
Working Frequency: 315MHz / 433MHz
Channel: 12 CH
12 Control Modes: Toggle, Momentary, Latched, Toggle + Momentary + Latched, Toggle + Latched, Momentary + Latched, Toggle + Momentary
Static Current: ≤6mA
Maximum Working Current: 5A / each channel
PCB Size: 94mm x 73mm x 18mm
Case Size: 100mm x 80mm x 30mm
Work with Fixed code transmitters
Product Description:
Model No.: 0021029 (CB-12)
Shell Color: Grey
Channel/Button: 12
Button Symbol: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12
Operating Voltage: 9V (1 x 6F22 -9V battery, can be used for 12 months)
Operating Current: 30mA
Operating Frequency: 315Mhz / 433Mhz
Encoding Chip: PT2262 / PT2264 / SC2262
Encoding Type: Fixed code by soldering, up to 6561 codes
Transmitting Distance: 1000m / 3000ft (theoretically)
The distance of 1000m is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will be hindered by trees, walls or other constructions, and will be exposed to some interference by other signals. Therefore, the actual distance may or may not reach 1000m.
If you stretches the telescopic antenna, it can have a further working range, which is twice as much as it used to be.
Modulation Mode: ASK
Operating Temperature: -20 ° C to +70 ° C
Unit Size: 135mm x 42mm x 25mm
Weight: 95g
Uses: garage doors, motorcycles, car alarm products, home security products, wireless remote control products, industrial control products.
How to set up the 8-bits code of the transmitter:
1. Open the transmitter shell, then you will see the circuit board. There are two rows pads and one row of chip feet on the back side.
2. The upper row of pads is “L” side, and the lower row of pads is “H” side.
3. If solder the middle row of chip feet to the “L” side, it is code 1. If solder the middle row of chip feet to the “H” side, it is code 2. Don't solder to any side, it is code 0.
4. The 8-bits code order is from left to right (from A1 to A8).
5. Here is an example, the 8-bits code in the picture is 00010121, solder as the following way:
6. Code 0: don't solder any side, like A1、A2、A3、A5.
7. Code 1: solder to the “L” side, like A4、A6、A8.
Matching Transmitters:
The receiver can work with different transmitters, such as model CV-12 (500M), or CB-12 (1000M) etc.
Working Range:
Super long range, with a transmitter (such as CB-12 to form a complete set, the maximum working distance can reach 2000M in an open ground.
The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will be hindered by trees, walls or other constructions, and will be interfered by other wireless signals. Therefore, the actual distance may not reach this maximum working distance.
Magnetic Sucker Antenna:
Frequency Range: 300~450MHz
Impedance: 50Ω
Antenna Length: 15cm
Cable Length: 1.5m, we also can offer longer cable, such as 5meters, 10meters, 30meters.
Anti-interference, waterproof, shielded wire set inside.
Magnetic stand design for easy to install.
Usage (with the transmitter CB-12):
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The receiver is relay output, not DC/AC power output. Initial state of relay output terminals: Terminals B and C are Normally Open; Terminals A and B are Normally Closed.
Wiring:
If you want to control a DC 12V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “+” of INPUT, and connect the negative pole of DC power supply to terminal “-” of INPUT.
2) Connect terminal C to the positive pole of DC power supply, connect terminal B to the positive pole of DC lamp, and connect the negative pole of DC lamp to the negative pole of DC power supply.
If you want to control an AC 220V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “+” of INPUT, and connect the negative pole of DC power supply to terminal “-” of INPUT.
2) Connect terminal C to the live wire of AC power supply, connect terminal B to one side of AC lamp, and connect another side of AC lamp to the neutral wire of AC power supply.
Setting different control modes:
Setting different control modes (We have set the receiver as Toggle control mode before delivery. If you want to use other control modes, do as following operation):
1) Learning Toggle control mode: When the receiver is in the status of LEARNING, press button 1 of the remote control.
Control mode Toggle (Channel 1~12): Press -> On; Press again -> Off.
Press button 1: Turn on relay 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Press button 1 again: Turn off relay 1 (disconnect B and C, connect A and B), the lamp 1 is off.
…
Press button 12: Turn on relay 12 (connect B and C, disconnect A and B), the lamp 12 is on.
Press button 12 again: Turn off relay 12 (disconnect B and C, connect A and B), the lamp 12 is off.
2) Learning Momentary control mode: When the receiver is in the status of LEARNING, press button 2 of the remote control.
Control mode Momentary (Channel 1~12): Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on relay 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Release button 1: Turn off relay 1 (disconnect B and C, connect A and B), the lamp 1 is off.
…
Press and hold button 12: Turn on relay 12 (connect B and C, disconnect A and B), the lamp 12 is on.
Release button 12: Turn off relay 12 (disconnect B and C, connect A and B), the lamp 12 is off.
3) Learning Latched control mode: When the receiver is in the status of LEARNING, press button 3 of the remote control.
Control mode Latched (Channel 1~12): Press -> On, other relays Off; Press other button -> Off.
Press button 1: Turn on relay 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Turn off other relay (disconnect B and C, connect A and B), other lamps are off.
…
Press button 12: Turn on relay 12 (connect B and C, disconnect A and B), the lamp 12 is on.
Turn off other relay (disconnect B and C, connect A and B), other lamps are off.
4) Learning Toggle (Channel 1~4) + Momentary (Channel 5~8) + Latched (Channel 9~12) control mode: When the receiver is in the status of LEARNING, press button 4 of the remote control.
5) Learning Toggle (Channel 1~6) + Momentary (Channel 7~12) control mode: When the receiver is in the status of LEARNING, press button 5 of the remote control.
6) Learning Toggle (Channel 1~6) + Latched (Channel 7~12) control mode: When the receiver is in the status of LEARNING, press button 6 of the remote control.
7) Learning Momentary (Channel 1~6) + Latched (Channel 7~12) control mode: When the receiver is in the status of LEARNING, press button 7 of the remote control.
8) Learning Latched (Channel 1~4 interlocked; Channel 5~8 interlocked; Channel 9~12 interlocked) control mode: When the receiver is in the status of LEARNING, press button 8 of the remote control.
9) Learning Toggle (Channel 1~10) + Momentary (Channel 11~12) control mode: When the receiver is in the status of LEARNING, press button 9 of the remote control.
10) Learning Toggle (Channel 1~4) + Momentary (Channel 5~12) control mode: When the receiver is in the status of LEARNING, press button 10 of the remote control.
11) Learning Toggle (Channel 1~4) + Latched (Channel 5~12) control mode: When the receiver is in the status of LEARNING, press button 11 of the remote control.
12) Learning Toggle control mode (Channel 1~10) + All On / Off (Channel 11/12): When the receiver is in the status of LEARNING, press button 12 of the remote control.
Press button 11: Turn on all 12 relays
Press button 12: Turn off all 12 relays
Personne à contacter : remotecontrol rf, 8008208820
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de Carymart Rechercher dans la catégorie : Artisanat Rechercher dans la catégorie : carymart |
Vendredi 02 août 2013
Quantité : ≥1 - Prix : USD510-530
External appearance size 1200*280*1000 Passage breadth Q600 mm pole of barrier long 530 mm 1. 1.IC, ID, the card of Magnetic force, bar code card etc. variety reads and writes the way can be provided as choice 2. Having the power failure meets an emergency the function...
semtong
- 86 - Shenzhen
- 075583218928
Jeudi 19 juillet 2012
Quantité : 100 - Prix : 1,00 €
THE description of the product Down lighting fixtures 7: Model NO.: XB-LD0007 Place of origin: Xiamen,China Brand: ADAMLIGHT Packaging: Carton Dlivery time: 10 -20 days MOQ: 100 pcs Supply Capacity: 50000 pcs per week high power LED down light 1. Long life time: 5000Hrs 2. CE and ROHS...
- newsun10596
- -
- +15 3 59 35 52 82
Samedi 22 décembre 2012
Quantité : 500 - Prix : $80