Car lube oil analysis kit
Prix : $2600 per set
Ⅰ.Product efficacy: | ||
Main Functions:
|
Product Advantages: |
◆Determining the degree of contaminate in lubricants |
◆The quick test realizes an "oil replace based on quality" |
Ⅱ.Product Description: | ||
- THY-22B Oil Quality Analyzer is a portable, intellectualized, small-sized product, The instrument uses a low voltage, micropower signal conditioning and data processing systems, can work to use ordinary AA batteries. It will shut off automatically under unmanned operation or low battery condition .
Mian Features | Technical Specifications | ||||||||||||||
1. small size, portable enable us to use it by hand. 2. Intelligent, auto 0-adjusting user-friendly operation 3. LCD screen, make testing results more intuitive |
|
Ⅲ.Main Benefits: | ||
Saves you time, money, breakdowns.
Accurately measures quality of oil in service.
Shows total contamination of lubricant.
Allows you to safely judge how long the oil can stay in service.
Determines safe and cost effective oil and filter change intervals.
Enables you to safely extend oil change intervals.
Alerts you to potential equipment malfunction and/or failure before it happens.
Saves frequent and unnecessary lab tests - it tells you when and if you need a lab test.
Ⅳ.Application Method | ||
-
Power on
1. Put the analyzer on the horizontal table.
2. Press the key of 【ON】, the analyzer conducting self-checking, and the analyzer enter in standby status after “welcome to use THY-22B ” showed on the LCD screen. Then LCD will go to "TEST? VOLTAGE?" automatically, you can choose oil measurement function or voltage function according to your requirement.
Quick Test(QT)
1.Press key of【QT】, and the LCD shows “CLEAN OIL CHAMBER,ENTER?”, clean the oil chamber with 60-90℃petroleum ether , then wipe the oil chamber with absorbent cotton(twice).
2.Press key of 【ENTER】, the LCD screen shows"SELF-CHECKING, PLEASE WAIT"
3.The LCD screen shows: "PUT PURE,ENTER?" after finishing self-checking, then drip new good oil 4~5 drops (up and down) into the oil chamber, when oil get fully contact in oil chamber,immediately to press key of 【ENTER】, and LCD screen shows" PLEASE WAIT……", and unit enters in status of new oil testing.
4.LCD screen shows" CLEAN OIL CHAMBER, ENTER?" after finishing new oil test, clean the oil chamber with 60-90℃petroleum ether , then wipe the oil chamber with absorbent cotton(twice).
5.Press key of 【ENTER】, the LCD screen shows"SELF-CHECKING, PLEASE WAIT"
6.The LCD screen shows: "PUT OLD,ENTER?" after finishing self-checking, then drip measured oil 4 ~5 drops (up and down) into the oil chamber, when oil get fully contact in oil chamber, immediately to press key of 【ENTER】, and LCD screen shows" PLEASE WAIT……", and unit enters in status of contaminated oil testing.
7.The LCD screen shows detecting result as following:
a.When showing "VALUE= ***.*%, TEST OK Continue to Use! ", it indicates the quality of your oil is in good condition, so the oil can be continued to use.
b.When showing "VALUE= ***.*%, Use or Change!", it indicates the quality of your detected oil is close to value of the scrap oil, but is still qualified, so the oil can be continued to use or change
c.When showing "VALUE= ***.*%, change oil!", it indicates the oil is out of standardand you must change oil at once.
8.Press key of 【ENTER】after finishing test, the LCD screen shows" CLEAN OIL CHAMBER, TEST? VOLT? POWER OFF?"
9.You can choose oil measurement or voltage measurement or power off according to your requirement.
Remark:
1.If testing value is between "0-50', which means the detected oil can be continue to use.
2.If testing value is between "50-80', which means the detected oil can be continue to use or change.
3.If testing value is more than "80", which means you must change oil at once.
VOLTAGE
1.Press key of 【VT】,the LCD screen shows operating voltage, normal operating voltage is “3.0—3.2V”.
2.LCD screen will shows " LOW VOLT, REPLACE" when your batteries run low.
3.LCD screen shows " INSUFFICIENT VOLT" when voltage is lower than operating voltage.
4.Press key of 【ENTER】after finishing test, LCD screen shows" TEST?VOLT? POWER OFF?"
5.You can choose oil measurement or voltage measurement or power off according to your requirement.
Ⅳ.Applications: | ||
Personne à contacter : Lawrence Chang, 86 29 86691978
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de Car lube oil analysis kit Rechercher dans la catégorie : Biens d'équipement Rechercher dans la catégorie : lube, analysis |
Samedi 25 mai 2024
Quantité : 5000 Tons/ - Prix : USD 500-100/ton fob
High Bulk C2S Art Board Name High Bulk FBB GC1/GC2 Color White Material 100% Wood Pulp Whiteness 91±1.5% Substance 200gsm-350gsm, etc Size 600*900mm, 700*1000mm, 787*1092mm, 889*1194mm or width >600mm in roll size, and any customized size. Packing PE film wrapped...
Golden Paper Company Limited
- 200333 - shanghai
- 00862158647533
Vendredi 24 juin 2022
Quantité : 100
Samsung Galaxy A71 128GO Argent 6.6" Android SM-A715FZSUDBT General Type Smartphone Compatible memory cards Extended Capacity SD (MicroSDHC) Display Display type Super-AMOLED Touchscreen yes (image-) diagonal 16,95 cm Screen size (inch) 6,6 " Technical specifications Flash memory...
MaKant Europe GmbH & Co. KG
- 60386 - Frankfurt am Main
- +49 (69) 9 150 750 14
Jeudi 12 septembre 2024
Quantité : 500 - Prix : 1 000,00 €
Apple iPhone 16 Pro,Pro Max Network Technology GSM / CDMA / HSPA / EVDO / LTE / 5G Body Dimensions 163 x 77.6 x 8.3 mm (6.42 x 3.06 x 0.33 in) Weight 225 g (7.94 oz) Build Glass front (Corning-made glass), glass back (Corning-made glass), titanium frame (grade 5) Interested Buyers...
Silas Electronics Ltd
- 75012 - Paris
- 6159292001