C01 Sleep Therapy System (Household Ventilator)
Product Profile:
Sleep apnea syndrome has been gradually taken to a serious threat of the most common illnesses to human health, has become invisible killer of lifethreatening at recently 30 years. Sleep apnea syndrome prevalence rate is 4% in the population, and the rate is 20% to 40% in people over 65 ages. The main feature of sleep apnea syndrome is that the patients have recurrent apnea during sleep and cause hypoxia leading to the ultimate consequences of cardiovascular and cerebrovascular disease, diabetes and other damage to many organs. 80% of drug resistant hypertension, 50% to 70% of congestive heart failure, nearly 50% of atrial fibrillation and diabetes has relationship with sleep apnea syndrome.
Since 1981, Dr. Sullivan from Australia firstly use continuous positive airway pressure breathing machine (CPAP) to treat the sleep apnea syndrome (OSA). Because of its safety, effective, less side effects, and efficient treatment characteristics, CPAP get more and more widely used. CPAP adapt to all types of sleep apnea hypopnea syndrome treatment, especially more effective for moderate and severe obstructive sleep apnea syndrome patients. In the various methods of treatment of sleep apnea syndrome at home and abroad, CPAP treatment accounted for 70-80% utilization.
Our company is grand to launch the ARI series CPAP/Auto CPAP, it has accurate and stable pressure output, incorporate humidifier, ramp up time setting and Auto On/Off functions, those will provide more comfortable during the sleep. Look forward to your finding more features.
Characteristic:
1. 3.5" TFT or 64X128 LCD Screen, ensures a friendly user interface.
2. One button operation makes the parameter setting easy;
3. Constant temperature humidifier can ensure comfortable airflow for patients;
4. The 0-60 minute ramp durations ensure patients fall asleep peacefully;
5. The latest technology of the different pressure sensor and automatic leakage and altitude compensation ensure the therapy accuracy anywhere.
6. Customized Germany motor and special sound-insulation material and design make noise low and let patients sleep well.
7. Patient breathing with the mask can trigger the machine automatically enter into working mode; Taking off the mask in working mode can make it into standby status automatically after 15 seconds, which is very safe and reliable.
8. Internal intelligent flash record every using case including real-time data, event information, etc. A USB port is provided for data download.
9. The intelligent monitoring system can provide an alarm timely, in case of any sudden power failure to ensure the safety treatment.
10. Automatic pressure titration for Auto-CPAP: Monitoring the real-time breath condition to finish the pressure titration automatically and separated from PSG or by hand to meet all kinds of requirements.
Specifications |
||||||||
|
||||||||
Name |
CPAP |
AutoCPAP |
BiPAP |
|||||
Model |
C02 |
C01 |
AC09 |
AC08 |
B19 |
B18 |
||
Colour |
Gray Shell / White Black Screen |
Silvery Shell/ Color Screen |
Silvery Shell / Color Screen |
Gray Shell/White Black Screen |
Silvery Shell/ Color Screen |
Gray Shell/White Black Screen |
||
Display |
3.5” TFT LCD |
128*64 LCD |
3.5” TFT LCD |
128*64 LCD |
3.5” TFT LCD |
128*64 LCD |
||
Working Mode |
||||||||
CPAP |
Y |
Y |
Y |
Y |
Y |
Y |
||
CPAP+EPR |
Y |
Y |
Y |
Y |
Y |
Y |
||
Auto CPAP |
Y |
Y |
||||||
Titration |
|
|
Y |
Y |
|
|
||
S |
Y |
|||||||
T |
Y |
|||||||
S/T |
Y |
Y |
||||||
Main Function |
||||||||
Pressure (increment 0.5 cmH2O) |
4-20cmH2O |
4-20cmH2O |
4-20cmH2O |
4-20cmH2O |
4-20cmH2O |
4-20cmH2O |
||
IPAP (increment 0.5 cmH2O) |
4-20cmH2O |
4-20cmH2O |
||||||
EPAP (increment 0.5 cmH2O) |
4-20cmH2O |
4-20cmH2O |
||||||
EPR (1-3 level) |
2-4 cmH2O |
2-4cmH2O |
2-4cmH2O |
2-4cmH2O |
2-4cmH2O |
2-4cmH2O |
||
Inspiration sensitivity (1-6 level) |
|
|
|
|
|
Y |
||
Expiration sensitivity (1-6 level) |
|
|
|
|
|
Y |
||
Respiratory Rate |
|
|
|
|
4-40 BPM |
4-40 BPM |
||
Inspiration time (0.5-3.0s) |
|
|
|
|
Y |
Y |
||
Ramp duration |
0-60 Min. |
0-60 Min. |
0-60 Min. |
0-60 Min. |
0-60 Min. |
0-60 Min. |
||
Automatic leakage compensation |
Y |
Y |
Y |
Y |
Y |
Y |
||
Automatic attitude compensation |
Y |
Y |
Y |
Y |
Y |
Y |
||
Auto ON/OFF |
Y |
Y |
Y |
Y |
Y |
Y |
||
Power Adapter (110-240Vac) |
Y |
Y |
Y |
Y |
Y |
Y |
||
Humidifier
|
||||||||
Adjustable constant temperature humidification system |
Y |
Y |
Y |
Y |
Y |
Y |
||
Replaceable water chamber (Max. 200ml) |
Y |
Y |
Y |
Y |
Y |
Y |
||
Alarms |
||||||||
Alarm for power off or disconnected |
Y |
Y |
Y |
Y |
Y |
Y |
||
Heated Humidifier |
Y |
Y |
Y |
Y |
Y |
Y |
||
Data Download |
||||||||
Data In Total (Apnea Hyponea Index /Data analysis, Adaptability, Usage Time) |
Y |
Y |
Y |
Y |
||||
Data In Details (AHI, Event, Pressure and Respiratory Flow) |
Y |
Y |
Y |
Y |
Y |
Y |
||
USB Connected With PC |
Y |
Y |
Y |
Y |
Y |
Y |
||
Other specification |
||||||||
Noise |
<30dBA (10cmH2O)</p> |
|||||||
System Time |
24hours |
|||||||
Backlight Time |
30,60,120,300,600 Seconds |
|||||||
Electrical specification |
Input: 100-240V,50-60Hz,1.7A Output: 24V,2.5A Class II, Type BF Applied Part |
|||||||
Work Environment |
T: 5℃-35℃, H: 15%-95%(No condensation),P: 77-101kPa |
|||||||
Storage Environment |
T: 20℃-60℃, H: 15%-95%(No condensation) |
|||||||
Waterproof grade |
IPX1 |
|||||||
Dimension,Weight |
390mm*280mm*195mm,1.0Kg (Host+Humidifier) |
Personne à contacter : Rachel Zhang, 86 755 27196156
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de C01 Sleep Therapy System (Household Ventilator) Rechercher dans la catégorie : Médical Rechercher dans la catégorie : therapy, ventilator, household, sleep, system |
Vendredi 01 décembre 2023
Automobile brake pads are essential components in automotive braking systems. They create friction against the brake rotors when the brake pedal is pressed, causing the vehicle to slow down or stop. Made of friction materials, they endure heat and pressure, ensuring safe and effective...
Qllino Automotive Industrial Limited
- 999077 - Lockhart RD
- 86 571 82789568
Jeudi 18 janvier 2024
Prix : 13955.57-697778.50 U
Industrial Equipment manufacturers are a crucial industry for the world, It is very diverse and comprises the manufacture of all mechanical machinery for use in mining, manufacturing, energy, and construction sectors. Regardless of the type of equipment, our goal is always the same...
- 200030 - shanghai
- 021 6958 0696
Lundi 02 décembre 2024
We offer quality Diabetic Test Strips and Monitoring systems products at very affordable and reachable prices. All our products are original and come with usage instructions. We have the following in stock; FREESTYLE OPTIUM NEO (H) 100T Accu chek performa 50 TS AccuCheck Active 50...
EVERYDAY ITEMS LTD
- pharmex
- M2 3WQ - Manchester
- +447565831644