BeVision D2
Dynamic Image Particle Analyzer with Dry Dispersion
The BeVision D2 particle image analyzer(particle shape analyzer) is a microscopic image particle size and particle shape analyzer for non-destructive measurement of coarse particles and millimeter range powder materials. BeVision D2 particle size analyzer's high speed CCD camera and multi-threaded software quickly identify particles and obtains stable and accurate measurement results.
Measurement type: particle shape; dynamic image analysis particle size Particle size range:
Dry: 30µm to 10000µm
Dry dispersion;
Technology: Automated Imaging
Overview
Features and Benefits:
● Measuring range: 30 - 10,000 µm (dry)
● Magnification: 9-300 times
● Repeatability: ≤1% (GBRM D50)
● Accuracy: ≤1% (GBRM D50)
● Optimized software: Identify 10,000 particles per minute. Automatic recognition of agglomerated powder .
● Analysis parameters: Particle size distribution, typical value, maximum particle size, D100, particle shape, aspect ratio, circularity and radius-thickness ratio.
● High-speed CCD camera: 120 images per second, microsecond exposure time, avoid trailing in moving particles .
● Sampler: Dry sampler using electromagnetic vibration feed, gravitydriven dispersion, suitable for coarse and agglomerated particles.
Performance
Dry dispersion provided by BeVision D2 particle size analyser makes it suitable for a diverse range of applications.
1. Accuracy Calibration
Use the scale to verify accuracy and convert the pixel to actual size during the test and analysis. Ensure the results are accurate and reliable.
2. Recognize Connected Paticles
The main purpose of the function is to filter agglomerate or adhesive particles, in order to avoid that test result is affected. Connected particles refer to agglomerate particles forming by two or more than two adhesive particles. The feature of connected particles is that there is sunken area in particle image. Through judging the size, depth and angle of the sunken area, connected particles can be recognized.
3. Automatic Circulation and Dispersion System
The dry system adopts electromagnetic vibration feeding, gravity-driven dispersion, which ensures sampling is uniform and continuous.
4. Application of BeVision D2 particle size analyzer
Dry method: Applies to analyze granular samples between 30 um to 10 mm, such as salt, sugar, plastic products, catalyst, abrasive, carbon products, sand, coal, coffee, refractory, food, polystyrene, glass, ceramics, fertilizer, medicine, ore, etc.
5. Imaging Theory of Free Falling Particles
Adopts high-speed CCD camera-120 images per second, microsecond exposure time, avoid trailing phenomenon in moving particle. More than 10 thousand particles could be analyzed per minute by the special image processing software. During the process of free falling of particles, shoot particle images which pass the lens randomly. Meanwhile, software quickly recognizes and processes particles, and screen displays images, particle size and particle shape data for each particle in real time. As it adopts high-speed CCD that can reach 100frame/min, thousands of particles can be shot and processed per minute, and image process software can recognize and extract adhesive particles automatically. These technologies improve analysis speed, precision and accuracy of particle image greatly.
Technology
Specification
BeVision D2 |
|
Material |
Suspension, emulsion, dry powder |
Testing parameter |
Particle size, particle shape, particle size distribution, etc. |
CCD |
Imaging speed 120 frames/s |
Measuring speed |
10000pcs/min |
Typical measurement time |
≤10min |
Size |
|
Size range |
Dry: 30-10000µm |
Accuracy |
≤1% (GBRM D50) |
Repeatability |
≤1% (GBRM D50) |
Magnification |
9-300 times |
System |
|
Supply voltage |
220/110VAC |
Dimension |
610mm x 300mm x 450mm (L x W x H) |
Weight |
26kg |
Computer specification |
|
Computer interface |
At least a USB2.0 port required |
Operation system |
Windows XP, Windows 7,8 or 10 |
Hardware specification |
500GB HD, CPU: I7 2600 or above; Memory: 4G or above; Mainboard: With PCI-E interface, long and short card slot. Monitor resolution: 1680*1050 or above |
At Bettersize, our mission is to provide best-in-class particle sizing and characterization instruments, comprehensive solutions and exceptional customer services. We provide particle size instrument, particle size image analysis software, laser particle sizing and etc. Want to know more? Please contact us.
Personne à contacter : Xu Spring , +15 1 41 55 76 96
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de BeVision D2 Rechercher dans la catégorie : Biens d'équipement Rechercher dans la catégorie : bevision |
Jeudi 08 octobre 2015
Prix : 900euros
H.S. Code Promo: 39041090 Pureté: 99% Apparence: Poudre blanche ou grains 1. granulés de hdpe vierges Caractéristique Ce granulé de HDPE est l'extrusion, qualité de tube avec une bonne résistance aux intempéries, une bonne dispersion de noir de carbone également une excellente résistance...
SA BANGKOK IMPORT AND EXPORT LTD
- 10110 - Bangkok
- +66 9 40 61 68 72
Jeudi 16 juillet 2015
Quantité : 2x 40feets - Prix : 340$
Blanc raffiné SUCRE DE CANNE ICUMSA 45 CARACTÉRISTIQUES : pour la consommation humaine Polarisation: 99,80 % MINIMUM HUMIDITÉ : 00.04 % maximum SULPHATEASH CONTENU: 00.04 % maximum GRANULATION : moyenne à fine SOLUBILITÉ : 100 % SEC ET écoulement libre RAYONNEMENT : NORMAL W / O...
PK - GLOBAL UNIT
- 50000 - Chiang Mai
- +66 6 14 84 85 39
Mardi 16 février 2016
Quantité : 10,000MT - Prix : 210 USD/MT CIF
Refined Sugar Icumsa 45 RBU, Icumsa 150, Icumsa 600-1200 Competitive prices & Current cropping Quality guarantee ICUMSA 45 is a highly refined sugar, and it is easily recognizable by its distinctive sparkling white color and pure Sucrose taste. It is suitable for human consumption...
KHUN JACK PARTNERSHIP LIMITED
- 50000 - CHIANG MAI
- +66 9 56 19 49 81