AD3000-SPD2 Air Oxygen Blender
AD3000-SPD2 Air Oxygen Blender
Pigeon Medical air neonatal oxygen blender PN2000-SPD2 is doubling the output by adding an extra flow meter. Now the medical concentrated gas can be supplied to two newborns simultaneously. It brings a huge significant benefit on man power and cost saving. Besides that, adult version of flow meter including 6-60LPM and 10-120LPM are also available for your selection.
PN2000-SPD2 is designed with a 3LPM bleed flow to ensure the flow accuracy which made the oxymixer match precisely to the needs and particular situation of each individual patient.
AD3000-SPD2 Air Oxygen Blender Working Principle
Attach the high-pressure air and oxygen hoses to the medical air blender oxygen delivery.
The flow meter outlet ports are locked automically until docking with the connector in order to avoid leakage. Thanks to the double-flow meters, the blender is possible to supply medical gas to two devices with the same oxygen concentration level and individual flow.
Features of AD3000-SPD2 Air Oxygen Blender
Flow meter from 0.1 to 1LPM and from 1 to 10LPM
Support dual output with double flow meters
Made with high quality aluminum alloy, anodic oxidation surface treatment
Adjust oxygen concentration level from 21% to 100%
Powered by pneumatic control, no electricity required
Mechanical alarm system by detection of pressure differential
Specification of Pigeon Medical AD3000-SPD2 Air Oxygen Blender
Model |
AD3000-SPD2 Air Oxygen Blender |
FiO2 |
21%-100% |
Flow Control |
0.1-1 & 1-10LPM |
Pressure |
Air/Oxygen@0.3-0.4MPa |
Alarm |
When gas supply pressure difference > 0.1MPa |
Alarm Noise |
> 57dB(A) |
Number of Output |
Dual |
Accuracy of FiO2 |
±3% |
Bleed Flow |
3LPM |
As one of medical ventilator companies, we can offer sorts of related products for sale, if you have needs, please contact us.
Personne à contacter : Zhou Alex , +18 8 98 65 17 88
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de AD3000-SPD2 Air Oxygen Blender Rechercher dans la catégorie : Matériels occasions Rechercher dans la catégorie : spd2, ad3000, oxygen, blender |
Mercredi 14 septembre 2016
Quantité : 5000 - Prix : 50,00 €
Corps Acier A216 WCB & GS-C25 & 1.0619 & GP240GH - Clapet Inox 420 - Siège Inox 420 - Soufflet Inox 321 - Presse étoupe Graphite Tige et volant montants tournants - Chapeau et presse étoupe boulonnés - A brides RF PN16/ PN25/40 - Commande par volant fonte - Peinture...
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935
Mercredi 14 septembre 2016
Quantité : 5000 - Prix : 50,00 €
Robinet à soupape PN 16/25/40 Acier moulé - Robinet à soupape PN 25‑40 - Construction suivant DIN 3356 - Diamètre : DN15 à DN300 - Chapeau boulonné à arcade - Presse-étoupe boulonné - Tige montante à filetage extérieur - Ecartement suivant EN 558‑1 Série 1 - Raccordement...
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935
Mercredi 14 septembre 2016
Quantité : 5000 - Prix : 100,00 €
Corps Acier A216 WCB & GS-C25 & 1.0619 & GP240GH - Clapet Inox 420 - Siège Inox 420 - Soufflet Inox 321 - Presse étoupe Graphite Tige et volant montants tournants - Chapeau et presse étoupe boulonnés - A brides RF PN16/ PN25/40 - Commande par volant fonte - Peinture...
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935