ACPS Anterior Cervical Plates
▶▶ Size Information
Code |
Names |
Specification |
243220423 |
ACPSII 4x23 |
4holes |
243220425 |
ACPSII 4x25 |
4holes |
243220428 |
ACPSII 4x27.5 |
4holes |
243220430 |
ACPSII 4x30 |
4holes |
243220638 |
ACPSII 6x37.5 |
6holes |
243220640 |
ACPSII 6x40 |
6holes |
243220643 |
ACPSII 6x42.5 |
6holes |
243220645 |
ACPSII 6x45 |
6holes |
243220648 |
ACPSII 6x47.5 |
6holes |
243220650 |
ACPSII 6x50 |
6holes |
243220853 |
ACPSII 8x52.5 |
8holes |
243220855 |
ACPSII 8x55 |
8holes |
243220858 |
ACPSII 8x57.5 |
8holes |
243220860 |
ACPSII 8x60 |
8holes |
243220863 |
ACPSII 8x62.5 |
8holes |
243220865 |
ACPSII 8x65 |
8holes |
243220868 |
ACPSII 8x67.5 |
8holes |
243220870 |
ACPSII 8x70 |
8holes |
341014012 |
Fixed angle screw |
φ4.0x12 |
341014014 |
Fixed angle screw |
φ4.0x14 |
341014016 |
Fixed angle screw |
φ4.0x16 |
341044018 |
Adjustable angle screw |
φ4.0x18 |
341044512 |
Adjustable angle screw |
φ4.5x12 |
341044514 |
Adjustable angle screw |
φ4.5x14 |
341044516 |
Adjustable angle screw |
φ4.5x16 |
341044518 |
Adjustable angle screw |
φ4.5x18 |
▶▶ Indications
A cervical plate is a medically designed implant used during spinal instrumentation and fusion procedures to provide neck stability. Cervical plates enhance the rate of fusion and, in some cases, may reduce the need for external bracing following surgery.
Indications for surgery include intractable pain, progressive neurologic deficits, and documented compression of nerve roots or of the spinal cord that leads to progressive symptoms. Surgery has not been proven to help neck pain and/or suboccipital pain.
▶▶ Products Advantages
Anterior Cervical Plate
● Center line alignment groove design
● Large bone graft window for easy observation of bone graft
● Pre-curved steel plate, in line with the physiological curve of the cervical spine
● Low-cut edge design, thickness 2.2mm
Anterior Cervical Screw
● Self-tapping screws to reduce the use of wire taps
● Distinguish screws by color, quickly distinguish diameter and type
● Fixed angle screws and adjustable angle screws are used together for different indications
▶▶ Medical Tips
The composition of the cervical spine
The cervical vertebrae and the skull constitute the occipital-cervical joint, with physiological lordosis, divided into upper cervical vertebrae (C1, C2) and lower cervical vertebrae (C3-C7)
ACPS development history
In 1964, Bohler reported the first case of anterior cervical application of plate screws to the treatment of lower cervical spine fractures.
In the 70s of the 20th century, Orzco and Tapies applied the AO short-segment H-shaped plate to the anterior cervical fixation.
In 1986, Morsche and other AO scholars first designed the Cervical spine locking plate (CSLP).
Indications (C2-T1)
Trauma, cervical degenerative disease, tumor, deformity, false joint formation, combined anterior and posterior surgery
Skills
Plate-fixed nail assembly: Restrictive system is suitable for strong fixation of trauma and tumor cases.
Plate-adjustable nail assembly: semi-restrictive system, which can place screws at multiple angles according to the intraoperative anatomy, and allows load sharing between the bone graft block and the nail plate structure; suitable for postoperative fixation of cervical degenerative diseases.
Steel plate-mixed assembly
The type of structure can be determined according to the anatomy or indications during the operation.
Increase operational flexibility and better adapt to surgical needs.
Personne à contacter : inature Tao, +86 13358048801
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de ACPS Anterior Cervical Plates Rechercher dans la catégorie : Médical Rechercher dans la catégorie : anterior, cervical, acps, plates |
Samedi 21 décembre 2024
Product ID: CS500ZP-800W Powered by a 800W stainless steel heating element, this electric charcoal lighter ignites charcoal in just 8-10 minutes without without lighter fluid or charcoal chimneys. The Z shape of the heating element can be easily place in the grill when start-up...
CHUN TAI ELECTRIC CO., LTD.
- chuntai
- 114 - TAIPEI CITY
- +886 2 87512922
Samedi 02 avril 2016
We are the first patented waterproof LED Corn light in China. LED Replacement Lamps for Metal Halide / High Pressure Sodium/High Intensity Discharge/CFL Material Private mode 6063 Aluminum thermal structure; High quality aluminum processing technique; Special su rface treatment process...
Shenzhen snuoer technology Co., LTD
- 518103 - shenzhen
- +86 755 18682173476
Dimanche 02 septembre 2007
LA CELLULETTE est la 1° sandale minceur avec tests d'efficacité effectués par un laboratoire Français agréé, prouvant un amincissement significatif en 28 jours d'utilisation. Une efficacité amincissante et anti capitons prouvée scientifiquement. Cette sandale présente une semelle...
deltapartners
- issy
- 92600 - ASNIERES SUR SEINE
- +33 1 41 11 34 34