PHASE - 2605 Annonces

Chine (Rép. pop) 710077 Divers
Cleaning Silica Gel Bonded HPLC Columns

Mardi 02 juillet 2019

The key to regenerating contaminated HPLC columns is to know the nature of the contaminants and to find the right solvent to remove. If contamination is caused by the accumulation of strongly retained materials during repeated injections, simple steps to remove these contaminants...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
A Brief Introduction To Syringe Filter

Lundi 01 juillet 2019

This is a useful weapon for experimental analysts to filter micro-samples quickly and effectively, such as sample pre-filtration, clarification, and filtration of particles, liquids, and gases sterilizing, etc. The structure of Hawach syringe filter The structure of Hawach syringe...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
The aim of flash column chromatography is to separate components from the mixture and...

Lundi 01 juillet 2019

The aim of flash column chromatography is to separate components from the mixture and purify it. Briefly, flash column chromatography allows samples to be separated through columns filled with gels. Flash column chromatography has been widely used in organic chemistry since its inception...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Product Highlights & Core Technique of Filter Membranes

Lundi 01 juillet 2019

Usually, there are two essential properties that end users are the most—extractability of the impurities and advantages of microporous polymer membranes. Extractability of The Impurities Scientific laboratories mostly apply the membrane product to filter samples, mobile phase, and...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Principles for Selecting SPE Cartridges Specifications

Lundi 01 juillet 2019

After selecting the type of SPE cartridges, we have to determine the specifications of the SPE cartridge. The principle of selecting the SPE cartridge specification is to first ensure that the SPE cartridge packing has sufficient capacity to retain the target compound 100% on the column...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
France 87270 Destockage
Moteurs Electriques tri-phasés Neufs

Samedi 29 juin 2019

Quantité : 16 - Prix : 200 à 400,00 €

Je vends des moteurs electrique Tri-Phase Neufs de marque AEG 7 de 7.5KW = 400,00 €/u 6 de 4 KW = 200,00 €/u 3 de 5.5 KW = 300,00 €/u Localisation : ZA OCEALIM Av St EXUPERY, 87270 COUZEIX, Personne à contacter : Ahmed Ennjimi, 05 55 37 13 44

FRAMAR Industrie

  • framar
  • 87270 - COUZEIX
  • 05 55 37 13 44
  • 06 63 54 16 17
Chine (Rép. pop) 710077 Divers
Normal & Reversed HPLC Column

Vendredi 28 juin 2019

Stationary Phase & Mobile Phase The stationary phase is used to separate the substances, which is packed into HPLC Column directly; Mobile phase is the carrier, which carries the substances into the stationary phase and goes through the stationary phase. It is gas in the vapor phase...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
The Brief Introduction to Flash Column

Vendredi 21 juin 2019

Flash chromatographic column, also called rapid chromatographic column(rapid column crossing, which means gradient elution, decompression or pressurization of the column), medium pressure chromatographic column(for example, rapid elution is achieved by pressurizing with nitrogen and...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
How does SPE Cartridge Work?

Vendredi 21 juin 2019

Normally SPE cartridge has two basic adsorption modes: target compound adsorption mode, impurity adsorption mode; 5 operation modes: gravity operation, manual positive pressure, centrifuge, negative pressure and positive pressure mode. Now let's review the whole process step by step...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Introduction to Vacuum Filtration

Jeudi 20 juin 2019

Basic Knowledge of Vacuum Filtration Based on the principle that under the same pressure (vacuum degree), the vaporization temperature of the water is lower than that of oil, scientists make practical equipment which is called vacuum filter. In fact, vacuum filtration is the most...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
The Differences Between PVDF and PTFE Membrane

Jeudi 20 juin 2019

PTFE stands for Poly Tetra Fluoroethylene. People generally call it non-sticking lining or easy-cleaning material. The material of PTFE has the characteristics of antiacid and antisolvent, which means it is hardly insoluble in all solvents. And PTFE is heat-resistant and with low...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
The Basic Knowledge of Selecting the Most Suitable Flash Column

Mercredi 19 juin 2019

The most important process of the whole purification is selecting the most suitable Flash column. And now we will talk about the key content of the column: stationary phase. Stationary phase, commonly known as filler, is the most central part of chromatography. When we choose the...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Introduction of HPLC Column From Hawach

Mercredi 19 juin 2019

Hawach Scientific sorts HPLC out of two series which are Xchroma and Echroma. Xchroma columns possess many and complete types of stationary phase(23 in total) with reliable qualities, while another one is cheaper among lower prices. Essential Technical Parameters Naming Rule It consists...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
The Brief Introduction to SPE Cartridges

Mercredi 19 juin 2019

SPE cartridges, with a full name of Solid Phase extraction cartridges, is also called the SPE column( solid phase extraction column). The solid phase extraction column/cartridges is a pretreatment device for the sample being analyzed, which developed from the chromatographic column...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 610000 Biens d'équipement
Carrier air compressor 06na2300s5ec-a00

Mardi 18 juin 2019

As reference: TYPE: Screw POWER: 415v / 3 phase Max operating amps: 221 amps FEATURES: 134a refrigerant Other Types: Carrier air compressor 06NA2300S5EC-A00 Carrier air compressor 06NW2300 Carrier air compressor for PERFORMANCE 17 24ACB7 Carrier air compressor for PERFORMANCE...

A&S Aerodynamic Co., Ltd

  • 610000 - chengdu
  • +86 28 65376575
  • 862865376575
Chine (Rép. pop) 214115 Bâtiment
Ultra Low Temperature Recirculating Chillers LC -25-5

Mardi 18 juin 2019

After running for a period of time, the normal operation of ultra-low temperature circulating water chiller needs comprehensive maintenance and maintenance. For many enterprises, due to the weak consciousness of daily maintenance, the cryogenic cycle water chiller has been used for...

Chine (Rép. pop) 214115 Bâtiment
Low Temperature Chiller LN -60-10

Mardi 18 juin 2019

We know that the low temperature chillers are complicated equipment. Even the switch process, if not according to the standard of operation or with no special maintenance, will inevitably lead to a decline in the refrigeration efficiency of the low temperature chillers and will greatly...

Chine (Rép. pop) 710077 Divers
ETo obtain accurate separation of your sample, mobile phase, and other liquid, the perf...

Samedi 15 juin 2019

ETo obtain accurate separation of your sample, mobile phase, and other liquid, the perfect tool that you need is laboratory filters. An analysis of physical specifications and performance specifications is required when selecting filters. Physical specifications for laboratory filters...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Learn about SPE Cartridges

Samedi 15 juin 2019

What is SPE Cartridge? The term SPE cartridges is short for Solid Phase Extraction cartridge. It is a kind of sample preprocessing equipment (extract, separate and concentrate) which is developed from the chromatographic column. SPE cartridge is mainly used for preprocessing of the...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
HPLC Column Silicone Matrix Properties and Scope of Application

Vendredi 14 juin 2019

Hawach introduced the properties and application range of HPLC column stationary phase in the silica gel matrix. Silica gel matrix: Silica gel, weakly acidic, has a strong memory, used to separate non-polar, weakly acidic compounds, oils, etc.; C18, a silica-based uncapped reversed-phase...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
NH2 HPLC Columns

Jeudi 13 juin 2019

NH2 HPLC columns can be used in the positive phase or in the negative phase, but it should be noted that the positive phase solvent and the negative phase solvent are usually not mutually soluble. New NH2 HPLC columns are preserved in the positive phase environment under normal circumstances...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Hawach QuEChERS Solutions

Jeudi 13 juin 2019

Package 1 QuEChERS extracting pesticide residues from plants Extraction box: 50 ml centrifuge tube + AOAC/EN salt pack 2 kinds of buffer salts: General buffer salt for phase-separation and pH-adjustment; Anhydrous magnesium sulfate completely separates water in the matrix from the...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Installation of the HPLC Column

Mardi 11 juin 2019

The installation of the HPLC column should be carried out in the following three steps: a. Unpack the HPLC column and confirm the type, size, date of manufacture, and solvent stored in the column. b. Unscrew the sealing plug from the joints at both ends of the column and put it back...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Functions of Hawach SPE Cartridges during Extraction

Mardi 11 juin 2019

Solid phase extraction (SPE) is a separation process by which compound that is dissolved or suspended in a liquid mixture, thereby being separated from other compounds in the mixture according to their physical and chemical properties. There are 4 general functions as below: 1.Matrix...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 510000 Biens d'équipement
MJ-SL400 Automatic PCB Loading Machine, Full Automatic Pcb Magazine Loader In SMT Line

Lundi 10 juin 2019

Features The operation panel words are simple and clear, the alarm is exact, PCB conveying buffer distance is adjustable. PLC control system ensures the stable operation without interference, and the software can offer the sound safety protection measures for machine with the reasonable...

Guangdong Moje intelligent Equipment Co,.LTD.

  • 510000 - Guangzhou City
  • 020 89817005
Chine (Rép. pop) 710077 Divers
How Does Vacuum Filtration Work?

Vendredi 07 juin 2019

Vacuum filtration is an operation of evacuating the air below the filter paper to maintain the pressure differential across the filter medium. It increases the rate of filtration through the force on the solution over gravity. When setting vacuum filtration, the first step is fitting...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
What Factors Should be Considered When Choosing Syringe Filter?

Jeudi 06 juin 2019

The main function of the microporous filtration membrane and syringe filter is to trap and filtering of the particles, bacteria and other impurities from the gas phase or liquid phase for separation, purification and purification purposes. The following factors should be considered...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
What Factors Should be Considered When Choosing Syringe Filter?

Jeudi 06 juin 2019

The main function of the microporous filtration membrane and syringe filter is to trap and filtering of the particles, bacteria and other impurities from the gas phase or liquid phase for separation, purification and purification purposes. The following factors should be considered...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Characteristics of Flash Columns

Jeudi 06 juin 2019

The fast liquid chromatography column optimization function, or “GO” function, converts the linear gradient into a step gradient and optimizes the elution conditions near the confirmed elution peak. First, purify a small portion of the sample with a small column and wait until the...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Structure of HPLC Columns

Jeudi 06 juin 2019

The empty column is assembled from column joints, column tubes, and filters. The HPLC columns joints are constructed with a low dead volume. The column joints are threaded assemblies at both ends, with 7/16-inch external threads on one end and 3/16-inch internal threads on the other...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Nombre de résultats par page : 6 30 150

Rechercher PHASE