ADSORBENT - 82 Annonces

Chine (Rép. pop) 710077 Divers
Improvement Of QuEChERS Pre-Processing Method

Mercredi 18 septembre 2019

Selection of scavengers The conventional QuEChERS method only uses PSA which is too simple single that can no longer meet the complex matrix samples examination experiments. GCB (graphitized carbon black) can effectively adsorb pigments, non-polar interferences such as sterol due...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Hawach SCX/MCX Cartridge

Mercredi 18 septembre 2019

Hawach SPE Cartridges are made of medical grade PP and forming in one time. Frits are made of UHMW-PE. There is a variety of models to choose, such as Normal Phase Cartridge, Reversed Phase Cartridge, Ion Exchanges Cartridge, Mixed Mode Cartridges and so on. Here, We would like to...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Adsorption chromatography

Mardi 17 septembre 2019

Adsorption chromatography uses the difference in adsorption capacity of substances in stationary phase adsorption to achieve separation of the mixture. The chromatographic process of adsorption chromatography is the process in which the mobile phase molecules compete with the material...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
SPE Technology Brief Introduction

Lundi 16 septembre 2019

The extraction is divided into liquid phase extraction (LLE) and solid phase extraction (SPE). SPE technology is a column chromatography separation process. The technology is a combination of liquid-solid extraction and column liquid chromatography. The combination of this technology...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
What’s the Point of Introducing C18E in D-SPE?

Vendredi 13 septembre 2019

Some samples (such as avocado, peanuts, olive oil, etc.) contain more fat. Due to the limited solubility of fat in acetonitrile, the recovery rate of some fat-soluble pesticides (such as HCB, DDT, etc.) is reduced. How to overcome the low experimental results caused by fat? You can...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Introduction To Flash Chromatography

Mercredi 11 septembre 2019

Flash chromatography is one of the methods in the preparation of liquid chromatography and is usually used for the separation of organic compounds. Flash chromatography has the advantages of ease of operation, low cost, and fast analysis. There are few other techniques for purifying...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
SPE Cartridges Structure

Mercredi 11 septembre 2019

The structure of the SPE cartridge is mainly divided into four parts: column tube, sieve plate, adsorbent and supporting device. The characteristics of each part are briefly introduced below. Column tube: A carrier for the adsorbent, made from serum grade polypropylene. Commonly used...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
The Separation Essence Of Different Chromatography

Mardi 10 septembre 2019

According to the separation mechanism of substances, Chromatography can be divided into adsorption chromatography, distribution chromatography, ion exchange chromatography and the like. The operation mode of the adsorption thin layer chromatography refers to that the adsorption capacity...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
The Basic Principle and Application of SPE Cartridges

Mardi 03 septembre 2019

The basic principle of SPE cartridges is that the liquid sample is made to pass through the adsorbent to retain the tested substance, and then the impurities are washed away with appropriate strength solvent, and then the tested substance is eluted with a small amount of good solvent...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Important Technical Parameters Of SPE Columns

Mercredi 14 août 2019

The important technical parameters of Hawach SPE Columns are the key points of selection. Material The material selection of the SPE column is very important. The column material is in direct contact with the test object or analyte. The quality of material selection determines the...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
The Importance Of Flash Columns In Chromatography

Lundi 12 août 2019

The rapid chromatographic method is a technology widely used in the separation and purification of active target compounds, such as organic compounds, natural products, and biological macromolecules. Rapid chromatographic method has the advantages of easy-operation, low-price, and fast-analysis...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
SPE Cartridge Packaging And Application

Jeudi 08 août 2019

Most common SPE cartridges are injection syringes made of polyethylene, in which there are two plugs made of polypropylene or fiberglass, with a certain amount of chromatographic adsorbent (filler) between the two plugs. SPE cartridges without sieve plate 1. Avoid “non-specific adsorption” 2...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
What Are The Applications Of Ion-Exchange Solid Phase Extraction?

Mardi 06 août 2019

Ion-exchange solid phase extraction is widely used in biological samples and environmental monitoring. During the extraction process, the pH of the sample is adjusted so that the solute is easily ionized. The solute is exchanged from the resin by changing the pH or increasing the...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Model Of Solid Phase Extraction

Mercredi 31 juillet 2019

Solid phase extraction (SPE), developed in the 1970s, can replace the traditional liquid-liquid extraction in many fields and has been applied more and more widely in the laboratory. The common solvent of SPE Hexane, isooctane, tetrahalide carbon, trihalomethane, dihalomethane, tetrahydrofuran...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
What are the Advantages and Principles of the SPE Cartridges?

Lundi 15 juillet 2019

The solid phase extraction cartridges (SPE column, or Solid Phase Extraction Cartridges, or SPE cartridges for short) is a sample pretreatment device for extraction, separation and concentration developed from a chromatography column. Mainly used in sample pretreatment of various foods...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Introduction of QuEChERS

Vendredi 12 juillet 2019

Characteristics of QuEChERS QuEChERS is a pretreatment method for pesticide residue detection. This paper refers to the products produced by our company. Its name comes from the acronyms of the words “Quick, Easy, Cheap, Effective, Rugged, Safe”, which are also the characteristics...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Pretreatment for Pesticide Residue Detection – QuEChERS

Vendredi 12 juillet 2019

Today, Hawach want to talk about the pre-treatment process for pesticide residue detection from the perspective of food safety – QuEChERS, and also tell you how to pre-treat pesticide residue food. Introduction The present analytical methods and determining techniques, pre-treatment...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Introduction to SPE Cartridges

Jeudi 11 juillet 2019

SPE column or SPE cartridges are based on liquid-solid phase chromatography theory, it is a kind of extraction, separation, concentrated sample preparation unit. Mainly used in sample pretreatment of various foods, agricultural and livestock products, environmental samples and target...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
QuEChERS Methods

Mercredi 10 juillet 2019

According to the research from the United States Department of Agriculture, the QuEChERS meth od which extracts pesticide from foods is fast, convenient, cheap, effective and secure. When it compares to the traditional SPE method, QuEChERS not only uses less solvent but also adopts...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Rapid Chromatography And Flash Column

Mardi 09 juillet 2019

Rapid chromatography Technology for the separation and purification of natural products and biological macromolecules. It has the advantages of easy operation, cheap price, and rapid analysis, and a few other technologies can match the rapid chromatography in the application of purifying...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Polymeric MCX SPE Cartridges

Mardi 09 juillet 2019

Polymeric MCX SPE cartridges are used to extract strongly alkaline compounds. MCX is a mixed strong cation exchange adsorbent obtained by bonding sulfonic acid groups on highly crosslinked PS/DVB surface. It has both reverse phase and cationic exchange retentive properties and good...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
The Product Composition of QuEChERS

Vendredi 05 juillet 2019

The product mainly includes two parts: extraction boxes and purification boxes. Extraction boxes include salt bags and 50 ml centrifugal tubes. Due to the high transportation cost of 50 ml centrifugal tubes and the general unacceptability of customer laboratories, more customers will...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
How Does SPE Extraction Work During the Whole Process?

Jeudi 04 juillet 2019

Activation, also known as solvation, add a suitable solvent to expand the functional groups on the adsorbent and remove possible interferences on the adsorbent. Equilibrium, remove the activated solvent to create a suitable solvent environment for sampling. Usually, use the same solvent...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Normal & Reversed HPLC Column

Vendredi 28 juin 2019

Stationary Phase & Mobile Phase The stationary phase is used to separate the substances, which is packed into HPLC Column directly; Mobile phase is the carrier, which carries the substances into the stationary phase and goes through the stationary phase. It is gas in the vapor phase...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
How does SPE Cartridge Work?

Vendredi 21 juin 2019

Normally SPE cartridge has two basic adsorption modes: target compound adsorption mode, impurity adsorption mode; 5 operation modes: gravity operation, manual positive pressure, centrifuge, negative pressure and positive pressure mode. Now let's review the whole process step by step...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
QuEChERS Method to Overcome Matrix Interference

Jeudi 20 juin 2019

Extraction is often susceptible to matrix interference. One analytical method is fine in this matrix but can become problematic in another matrix. If we encounter such a situation, how can we improve the QuEChERS method to overcome it? For pesticide residues, most of the food samples...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Easy to Understand the QuEChERS

Mercredi 19 juin 2019

Take the example of pear test to check whether a pear is up to the standard. Prepare the environment The first step: Suitable Acetonitrile salting-out extraction environment was prepared. Make the pears into a puree, take 10g to QuEChERS centrifuge tube of 50ml. Add extract solution...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
The Brief Introduction to SPE Cartridges

Mercredi 19 juin 2019

SPE cartridges, with a full name of Solid Phase extraction cartridges, is also called the SPE column( solid phase extraction column). The solid phase extraction column/cartridges is a pretreatment device for the sample being analyzed, which developed from the chromatographic column...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Learn about SPE Cartridges

Samedi 15 juin 2019

What is SPE Cartridge? The term SPE cartridges is short for Solid Phase Extraction cartridge. It is a kind of sample preprocessing equipment (extract, separate and concentrate) which is developed from the chromatographic column. SPE cartridge is mainly used for preprocessing of the...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Chine (Rép. pop) 710077 Divers
Hawach QuEChERS Solutions

Jeudi 13 juin 2019

Package 1 QuEChERS extracting pesticide residues from plants Extraction box: 50 ml centrifuge tube + AOAC/EN salt pack 2 kinds of buffer salts: General buffer salt for phase-separation and pH-adjustment; Anhydrous magnesium sulfate completely separates water in the matrix from the...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Nombre de résultats par page : 6 30 150

Rechercher ADSORBENT