Médical
Kirschner Wire
|
Product Name |
Product Code |
Specification |
Note |
Titanium Kirchner Wire |
362408120 |
Φ0.8 x 120 |
Sterilized |
Titanium Kirchner Wire |
362408130 |
Φ0.8 x 130 |
Sterilized |
Titanium Kirchner Wire |
362408150 |
Φ0.8 x 150 |
Sterilized |
Titanium Kirchner Wire |
362410120 |
Φ1.0 x 120 |
Sterilized |
Titanium Kirchner Wire |
362410140 |
Φ1.0 x 140 |
Sterilized |
Titanium Kirchner Wire |
362410150 |
Φ1.0 x 150 |
Sterilized |
Titanium Kirchner Wire |
362412120 |
Φ1.2 x 120 |
Sterilized |
Titanium Kirchner Wire |
362412150 |
Φ1.2 x 150 |
Sterilized |
Titanium Kirchner Wire |
362415120 |
Φ1.5 x 120 |
Sterilized |
Titanium Kirchner Wire |
362415150 |
Φ1.5 x 150 |
Sterilized |
Titanium Kirchner Wire |
362415200 |
Φ1.5 x 200 |
Sterilized |
Titanium Kirchner Wire |
362420120 |
Φ2.0 x 120 |
Sterilized |
Titanium Kirchner Wire |
362420150 |
Φ2.0 x 150 |
Sterilized |
Titanium Kirchner Wire |
362420200 |
Φ2.0 x 200 |
Sterilized |
Titanium Kirchner Wire |
362420230 |
Φ2.0 x 230 |
Sterilized |
Titanium Kirchner Wire |
362425120 |
Φ2.5 x 120 |
Sterilized |
Titanium Kirchner Wire |
362425150 |
Φ2.5 x 150 |
Sterilized |
Titanium Kirchner Wire |
362425200 |
Φ2.5 x 200 |
Sterilized |
Titanium Kirchner Wire |
362425230 |
Φ2.5 x 230 |
Sterilized |
Titanium Kirchner Wire |
362425240 |
Φ2.5 x 240 |
Sterilized |
Titanium Kirchner Wire |
362430120 |
Φ3.0 x 120 |
Sterilized |
Titanium Kirchner Wire |
362430150 |
Φ3.0 x 150 |
Sterilized |
Titanium Kirchner Wire |
362430200 |
Φ3.0 x 200 |
Sterilized |
Titanium Kirchner Wire |
362430250 |
Φ3.0 x 250 |
Sterilized |
Product Name |
Product Code |
Specification |
Note |
S.S. Kirchner Wire |
162425200 |
Φ2.5 x 200 |
Sterilized |
S.S. Kirchner Wire |
162425240 |
Φ2.5 x 240 |
Sterilized |
S.S. Kirchner Wire |
162425250 |
Φ2.5 x 250 |
Sterilized |
S.S. Kirchner Wire |
162430120 |
Φ3.0 x 120 |
Sterilized |
S.S. Kirchner Wire |
162430150 |
Φ3.0 x 150 |
Sterilized |
S.S. Kirchner Wire |
162430200 |
Φ3.0 x 200 |
Sterilized |
S.S. Kirchner Wire |
162430250 |
Φ3.0 x 250 |
Sterilized |
S.S. Kirchner Wire |
162435120 |
Φ3.5 x 120 |
Sterilized |
S.S. Kirchner Wire |
162435150 |
Φ3.5 x 150 |
Sterilized |
S.S. Kirchner Wire |
162435200 |
Φ3.5 x 200 |
Sterilized |
S.S. Kirchner Wire |
162435250 |
Φ3.5 x 250 |
Sterilized |
S.S. Kirchner Wire |
162440120 |
Φ4.0 x 120 |
Sterilized |
S.S. Kirchner Wire |
162440150 |
Φ4.0 x 150 |
Sterilized |
S.S. Kirchner Wire |
162440200 |
Φ4.0 x 200 |
Sterilized |
S.S. Kirchner Wire |
162440250 |
Φ4.0 x 250 |
Sterilized |
S.S. Kirchner Wire |
163440230 |
Φ4.0 x 230 |
Sterilized |
S.S. Kirchner Wire |
163440260 |
Φ4.0 x 260 |
Sterilized |
S.S. Kirchner Wire |
163440300 |
Φ4.0 x 300 |
Sterilized |
Product Name |
Product Code |
Specification |
Note |
S.S. Kirchner Wire |
162408120 |
Φ0.8 x 120 |
Sterilized |
S.S. Kirchner Wire |
162408130 |
Φ0.8 x 130 |
Sterilized |
S.S. Kirchner Wire |
162410120 |
Φ1.0 x 120 |
Sterilized |
S.S. Kirchner Wire |
162410140 |
Φ1.0 x 140 |
Sterilized |
S.S. Kirchner Wire |
162410200 |
Φ1.0 x 200 |
Sterilized |
S.S. Kirchner Wire |
162412120 |
Φ1.2 x 120 |
Sterilized |
S.S. Kirchner Wire |
162412150 |
Φ1.2 x 150 |
Sterilized |
S.S. Kirchner Wire |
162415120 |
Φ1.5 x 120 |
Sterilized |
S.S. Kirchner Wire |
162415150 |
Φ1.5 x 150 |
Sterilized |
S.S. Kirchner Wire |
162415200 |
Φ1.5 x 200 |
Sterilized |
S.S. Kirchner Wire |
162415250 |
Φ1.5 x 250 |
Sterilized |
S.S. Kirchner Wire |
162420120 |
Φ2.0 x 120 |
Sterilized |
S.S. Kirchner Wire |
162420150 |
Φ2.0 x 150 |
Sterilized |
S.S. Kirchner Wire |
162420200 |
Φ2.0 x 200 |
Sterilized |
S.S. Kirchner Wire |
162420230 |
Φ2.0 x 230 |
Sterilized |
S.S. Kirchner Wire |
162420250 |
Φ2.0 x 250 |
Sterilized |
S.S. Kirchner Wire |
162425120 |
Φ2.5 x 120 |
Sterilized |
S.S. Kirchner Wire |
162425150 |
Φ2.5 x 150 |
Sterilized |
▶▶ Medical Tips
Indications
K-wires are used for temporary fixation during some operations. After definitive fixation they are then removed. The pins are usually removed four weeks post operation.
They can be used for definitive fixation if the fracture fragments are small (e.g. wrist fractures and hand injuries). In some settings they can be used for intramedullary fixation of bones such as the ulna.
Tension band wiring is a technique in which the bone fragments are transfixed by K-wires which are then also used as an anchor for a loop of flexible wire. As the loop is tightened the bone fragments are compressed together. Fractures of the kneecap and the olecranon process of the elbow are commonly treated by this method.
K-wires come in different sizes, and as they increase in size, they become less flexible. K-wires are often used to stabilize a broken bone and can be removed in the office once the fracture has healed. Some K-wires are threaded, which helps prevent movement or backing out of the wire, although that can also make them more difficult to remove.
Bonne affaire : acheter au vendeur
Cette page concerne les importateurs et exportateurs de Kirschner Wire Rechercher dans la catégorie : Médical Rechercher dans la catégorie : wire, kirschner |
Samedi 23 novembre 2024
Product ID: CS500ZP-800W Powered by a 800W stainless steel heating element, this electric charcoal lighter ignites charcoal in just 8-10 minutes without without lighter fluid or charcoal chimneys. The Z shape of the heating element can be easily place in the grill when start-up...
Vendredi 29 avril 2016
Quantité : 680 - Prix : $68
Your concern is our concern,we are committed to your success. --ESINO Team HM-001 Desk Passive Training Bike with Exercise Pedals for Disabled on Alibaba Product Description Key Points: Product Name HM-001 fitness bike trainer Item NO HM-001 Materials ABS Plastic ...
Samedi 23 novembre 2024
1.With ISO&CE&CCC&BV&TUV Certificate 2.Having exported for more than 70 countries 3.Year exported rate more than 60% 4.Having more than 11 factories 5.Having the best engineer and equipment in china 6.Annual produce capacity up to 1000 sets hammer head QTZ80(6010)...