Pro / B2B
Fire Resistant Control Cable (2-4cores) 300-500V
|
Conductor |
rated voltage 300/500v |
||||||
|
Without Earth Conductor |
With Earth Conductor |
|||||
No. of Core X Cross Section |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Approx. Weight |
Nominal Overall Diameter |
Approx. Weight |
No*mm² |
No./mm |
mm |
mm |
mm |
kg/km |
mm |
kg/km |
2 Cores |
|||||||
2x1.5 |
7/0.53 |
0.5 |
0.5 |
7.7 |
70 |
8.2 |
80 |
2x2.5 |
7/0.67 |
0.5 |
0.5 |
8.8 |
100 |
9.6 |
120 |
2x4 |
7/0.85 |
0.5 |
0.5 |
9.8 |
140 |
10.5 |
170 |
3 Cores |
|||||||
3x1.5 |
7/0.53 |
0.5 |
0.5 |
8.7 |
90 |
10.5 |
100 |
3x2.5 |
7/0.67 |
0.5 |
0.5 |
9.5 |
125 |
10.7 |
150 |
3x4 |
7/0.85 |
0.5 |
0.5 |
11.5 |
180 |
12.5 |
220 |
4 Cores |
|||||||
4x1.5 |
7/0.53 |
0.5 |
0.5 |
10.3 |
105 |
12.2 |
120 |
4x2.5 |
7/0.67 |
0.5 |
0.5 |
11 |
155 |
13 |
190 |
4x4 |
7/0.85 |
0.5 |
0.5 |
12.5 |
255 |
13.5 |
270 |
Description of Fire Resistant Control Cable (2-4cores) 300-500V
Rated voltage: 300/500V
Basic standard: BS 7211
Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228 class 2
Fire lyer: Mica glass tape
Insulation: PVC (XLPE)
Sheath: LSZH compound to BS 7655-6.1
Operating temperature range (fixed state): -30°C – +90°C
Operating temperature range (mobile state): -20°C – +50°C
Min bending radius: 6 times of Overall Diameter
Insulation resistance: 20 MΩ x km (at 20°C)
Short circuit temperature: 250°C
Circuit Integrity |
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); |
|
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); |
|
NF C32-070-2.3(CR1) |
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; |
|
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); |
|
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- |
|
004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; |
|
CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; |
|
CEI 20-37/2-2 ; BS 6425-2* |
Minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; |
|
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases |
NES 02-713; NF C 20-454 |
Application Of Fire Resistant Control Cable (2-4cores) 300-500V
The cables are designed for facilities where keeping and maintaining integrity of the electrical circuit is critical in power supply system.
The cables are widely used in underground tunnels, emergency lightings, fire alarm systems, control and power circuits, power stations, lifts, escalators, and high-rise buildings.
Bonne affaire : acheter au vendeur
Cette page concerne les importateurs et exportateurs de Fire Resistant Control Cable (2-4cores) 300-500V Rechercher dans la catégorie : Pro / B2B Rechercher dans la catégorie : fire, cable, control, 500v, 4cores, resistant |
Vendredi 27 septembre 2013
Quantité : 7 - Prix : 1,00 €
Nous vendons sauf vente entre temps ces nos 7 machines RYOBI qui sont disponible de suite : * Ryobi 512, Année 1997 36,5x52 - 2 couleurs - Mouillage Standard - Margeur à Nappes - Contrôle du réctificateur et du double feuille - Barres de calage rapide - Cylindre d'impression chromé...
Jeudi 02 janvier 2025
Prix : 650usd
Nous déclarons que nous sommes prêts, disposés en mesure de fournir et vendre de grade «A» Pieds de poulet transformés . Nous avons une certaine quantité raisonnable du produit à vendre . Voici les détails de notre produit de notre usine et nos conditions de vente : Produit : Pieds...
Jeudi 15 novembre 2007
WSC SARL Contact : Velizar Todorov (Mr) Tel : 00352 22 9999 5523 Mobile : 00352 661 655565 Fax : 00352 22 9999 5499 Luxembourg Lot de Barrières autoalimentées, télécommandées, pour protéger un parking privé ou empêcher le passage vers une voie d'accès privée. Prévue pour les emplacements...