400 Tr Cooling Tower
Closed Circular Cross Flow Cooling Tower(AHC)
It refers to a cooling tower in which the cooling hot water passes through the packing from top to bottom, while the air flows through the packing from horizontal and oblique directions, and the flow direction of hot water and the air is nearly 90 degrees (some manufacturers also call it direct cooling tower).
Features Of Closed Circular Cross Flow Cooling Tower
a. Crossflow cooling mode is adopted, and the bleaching rate is very low;
b. The internal space of closed circular cross flow type cooling tower is large and the maintenance is very convenient;
c. Totally closed circulation to eliminate the blockage caused by sundries;
d. The heat exchanger adopts the stacking mode of building blocks, which can be installed and disassembled layer by layer;
e. The closed type cooling tower using hot water circulation, no scale formation;
f. This wet and dry cooling tower does not need a pool, occupies a small area, and is easy to locate.
Structural Drawing Of Closed Cross Flow Cooling Tower
Application Scope Of Closed Circular Cross Flow Cooling Tower
The closed circular cross flow cooling tower fan adopts a silent large blade fan, which makes the noise at the outlet of the cooling tower lower. The gravity pool type water distribution is adopted. The spray water enters into the basin and then passes through the nozzle under the action of gravity. The heat exchange filler under the spray and the heat exchanger of the closed cooling tower. After passing through the heat exchanger, it naturally flows into the bottom sump. Therefore, the noise of a closed circular cross flow cooling tower is lower than that of a closed counter flow cooling tower. There was no sound of water dripping into the pan. Compared with the counter flow cooling tower, the closed circular cross flow cooling tower can be assembled side by side, which has a smaller floor area. Therefore, the cross-flow closed cooling tower is more suitable for occasions with high noise requirements and a small floor area.
Square Cross Flow Cooling Tower (AH)
The cross flow tower is the abbreviation of cross flow cooling tower. The cross flow tower refers to equipment that the fresh air was forced suctioned from two sides under the action of the fan and motor, while the water drops flow from top to bottom in the filler by gravity.
The flow direction of the air and water is 90° angle, mass transfer and heat transfer are carried out in the filler.
Specifications Of Square Cross Flow Cooling Tower
Details Of Square Cross Flow Cooling Tower
Reducer & Fan
Reducer: Transmission bearing chooses import NSK or NTN standard axle bearing, long service life and is not easy to damage, belt choose the import high strength V belt, high strength, wear resistance, long service life. Also, provide the AOSUA patent reducer with an external visualization device.
Fan: Use a high-quality aluminum alloy cross fan with an adjustable angle. Meet customer's different requirements for the process like a blast capacity. The fan must through strict balance and orientate before delivery, four-leaf forward plate-type design, to make the force of every piece is small, advantages: little vibration, low noise, high efficiency, power saving.
Petals Nozzle
The nozzle is made of ABS plastic one-time injection molding with high strength long service life. The nozzle water distribution is uniform, work pressure is low, widely suitable pressure range, and not easy to jam. Because of its locking and anti-loosening device, make the connection of it and the water distribution tightly, not shed, ensure long-term safe operation of the water distribution system. Under the condition of normal use, the service life of the nozzle is 20 years. Good heat dissipation effect, especially suit for power plant cooling water.
Fill
This cross flow type cooling tower uses the AOSUA designer's latest research and test results, anti-UV and corrosion resistance PVC vacuum forming molding,good entirety rigidity after assemble, low air resistance, remarkable thermodynamic performance.
The Casing
The square type cooling tower owns material that is FRP composite,surface gel coat use imported raw material, inside the colour has an anti-UV stabilizer, smooth surface, aging resistant.
Steel Frame
The open circuit cooling tower is made of international superior angle iron, high intensity, good durability. All the steel frames through strict hot-dip galvanizing, good preservative effect, high intensity, easy to assemble. The corrosion process accord with the British standard BS ENIS01461: 1999 standard.
Square Counter Flow Non-basin Cooling Tower(AFW)
The square counter flow non-basin cooling tower refers to the cooling tower without a basin. Its principle is the same as a counter-flow square tower. The water flow falls vertically in the tower, and the direction of airflow is opposite to that of water flow. The water exchanges heat and mass with the air flowing through it, resulting in a drop in water temperature.
Precautions for installation of Square Counter Flow Non-Basin Cooling Tower
A、 Appropriate installation site should be selected
The ground bearing capacity should refer to the operating weight of the cooling tower and the design installation coefficient to check the bearing capacity of the installation foundation.
Environmental conditions:
a. The short distance between the air inlet end and adjacent buildings shall not be less than 1.5 times the tower height.
b. It should not be installed in substations, boiler, and other places with a heat source. Keep the top of the tower away from an open fire.
c. It should not be installed in places where corrosive gas exists, such as chimneys and hot springs.
B、 Installation instructions:
a. The foundation of the counterflow cooling tower shall be embedded with a horizontal steel plate according to the specified size. The height of each foundation surface shall be on the same horizontal plane, and the elevation error shall be within 1 mm, and the middle error of the intersection shall be within 2 mm.
b. The tower body should be placed horizontally, and the whole foundation should be built if possible.
c. When installing the water tower, the installation personnel should step on the reinforcing ribs of the chassis to avoid crushing the chassis. In addition, when installing the card shell, chassis and other fiber arts, the screws should be inserted first, and then gradually tightened in order to avoid deformation of the shell and chassis. Confirm that the chassis is not deformed, and the contact area and nearby are clean. Only when it is dry can the fiber blanket and resin be set at the joint to avoid water leakage.
As one of the most professional cooling tower suppliers, we provide cooling tower tr, china cooling tower and etc. Contact us to know what is tr in cooling tower or more.
Personne à contacter : AUVC ctauvc, 057582331987
Bonne affaire : acheter au vendeur
Nous vous invitons à lire nos conditions générales d'utilisations. Vous pouvez aussi vous rendre sur nos FAQ et consulter notre page d'informations sur les risques liés à la contrefaçon.
Cette page concerne les importateurs et exportateurs de 400 Tr Cooling Tower Rechercher dans la catégorie : Pro / B2B Rechercher dans la catégorie : tower, cooling |
Jeudi 21 novembre 2024
réfrigérateurs americain Samsung
Quantité : 1000 - Prix : 590,00 €
Offre exceptionnelle : Lot de 1000 réfrigérateurs américains Samsung RS68CG882ES9 à prix déstockage ! Saisissez cette opportunité unique avec un lot de 1000 réfrigérateurs américains Samsung RS 68 CG 88 2E S9 à un prix de déstockage exceptionnel de 590 €/unité par 500 unités. Ce modèle haut de gamme est parfait pour les grossistes cherchant à proposer à leurs clients un produit combinant design élégant, technologie avancée, et performance énergétique. Caractéristiques principales...
TRANSIDI
- 22440 - PLOUFRAGAN
- 02 30 96 63 26
- 33(0)603670505
Vendredi 15 décembre 2017
online katalogOEM PART NO DESCRİPİTİON 66072 Crown Wheel and Pinion FOR CARRARO 13X30 66941 Crown Wheel and Pinion 15x37 2277448 CATERPİLLAR AİR FİLTER OUTER 2277449 CATERPİLLAR AİR FİLTER İNNER 01/117901 FAN BELT 01/124403 FAN BELT 01/124404 02/100073 Oil Filter Canister Type, MEDİUM...
ANAC MAKINA CO LTD STI
- 34800 - İSTANBUL
- +905069691531
- +9005069691531
Dimanche 02 septembre 2007
LA CELLULETTE est la 1° sandale minceur avec tests d'efficacité effectués par un laboratoire Français agréé, prouvant un amincissement significatif en 28 jours d'utilisation. Une efficacité amincissante et anti capitons prouvée scientifiquement. Cette sandale présente une semelle...
deltapartners
- issy
- 92600 - ASNIERES SUR SEINE
- +33 1 41 11 34 34